| Click for Specifics | Light | 4/23/2025 | 5/13/2025 | | 0 | | -- | 0 | | 215 | 215 | No | No | No | |
| Click for Specifics | Full | 5/14/2024 | 5/30/2024 | | 0 | No Flow | -- | 0 | No Flow | 184 | 183 | No | No | No | Annual Test. 0 PSI, with no pressure or flow observed for the entire 30-minute test. PDC will monitor pressure and re-test according to bradenhead policy. |
| Click for Specifics | Full | 6/27/2023 | 7/3/2023 | | 0 | No Flow | -- | 0 | No Flow | 245 | 243 | No | No | No | Annual Test. 0 PSI, with no pressure or flow observed for the entire 30-minute test. PDC will monitor pressure and re-test according to bradenhead policy. |
| Click for Specifics | Full | 5/25/2022 | 6/13/2022 | | 0 | No Flow | -- | 0 | No Flow | 330 | 329 | No | None | None | |
| Click for Specifics | Full | 10/18/2021 | 11/1/2021 | | 0 | No Flow | -- | 0 | No Flow | 437 | 437 | No | None | None | |
| Click for Specifics | Light | 11/23/2020 | 12/14/2020 | | 0 | | -- | 0 | | 650 | 650 | No | No | No | |
| 402613476 | Form 17 | 7/24/2020 | 3/1/2021 | | 0 | DOWN TO 0 | GAS | 0 | NO FLOW | 545 | 553 | No | -- | -- | Abatement system follow up test 0 PSI no pressure or flow, PDC will monitor pressure and re-test in 6 months. |
| 402225056 | Form 17 | 10/22/2019 | 10/29/2019 | FLOWING | 53 | DOWN TO 0 | -- | 0 | NO FLOW | 765 | 765 | Yes | Yes | -- | Annual test 53 PSI blew down to 0 PSI within first minute of test, no pressure or flow observed for the remainder of the test. PDC has collected a sample and will submit results via form 43. PDC will submit a remediation plan via sundry. |
| 401249232 | Form 17 | 3/30/2017 | 4/3/2017 | FLOWING | 200 | CONTINUOUS | -- | 0 | NO FLOW | 1750 | 2248 | No | -- | -- | |
| 401122567 | Form 17 | 9/16/2016 | 10/3/2016 | SHUT-IN | 170 | GAS | -- | 0 | NO FLOW | 0 | 0 | No | -- | -- | |