Skip to Main Content

Incident Search

 
BradenheadView Related Related View DocsDoc
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation ID
WELL05-123-42690Connie
26F-302
PDC ENERGY INC
69175
PR
10/1/2024
WATTENBERG
90750
WELD  123
NWNW 26 5N64W 6
444694
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 1467 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
404161215Form 174/9/20254/10/2025PLUNGER LIFT10CONTINUOUS GAS1 WHISPER 337331No----Annual Test. 10 PSI continuous gas blew down to 1 PSI within thirty minutes of test. Whisper gas observed for entire test. Operator will schedule a sampling event and submit results via form 43. Operator will monitor pressure and re-test according to bradenhead policy.
403774247Form 174/19/20244/30/2024 7DOWN TO 0 GAS0 NO FLOW 279280No----Abatement system follow up test. 7 PSI gas flow blew down to 0 PSI within first five minutes of test. No pressure or flow observed for the remainder of the test. PDC will monitor pressure and re-test according to bradenhead policy.
Click for SpecificsFull5/2/20235/8/2023 14Down to Zero--0No Flow428428NoNoneNoneAnnual Test. 14 PSI blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will monitor pressure and re-test according to bradenhead policy.
403038812Form 175/4/20225/5/2022PLUNGER LIFT35DOWN TO 0 GAS0 NO FLOW 302302No----Abatement system follow up test, 35 PSI gas flow blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will submit sundry with bradenhead details as soon as possible. PDC will continue to monitor monthly.
402865082Form 1710/24/202111/8/2021PLUNGER LIFT52CONTINUOUS --46 CONTINUOUS 323329Yes----Post-production, 52 PSI continuous flow blew down to 46 PSI in thirty minutes. PDC will submit sundry with bradenhead details as soon as possible. PDC will schedule a sampling event and submit results via form 43.
402865100Form 179/12/202111/8/2021PLUNGER LIFT64CONTINUOUS --60 CONTINUOUS 330330Yes----Post-production, 64 PSI blew down to 60 PSI in thirty minutes. PDC will submit sundry with bradenhead details as soon as possible. PDC will schedule a sampling event and submit results via form 43.
Click for SpecificsLight3/12/20205/11/2020 4 --4 474474NoNoNo 
Click for SpecificsLight3/26/20198/18/2020 0 --0 594594NoNoNo 
401190462Form 171/14/20171/20/2017FLOWING90DOWN TO 0 --0 NO FLOW 22702270No---- 
401176770Form 1712/22/20161/3/2017FLOWING90DOWN TO 0 --0 NO FLOW 26482648No---- 
401064247Form 176/8/20166/17/2016SHUT-IN0NO FLOW --0 NO FLOW 00No----