Skip to Main Content

Incident Search

 
BradenheadView Related Related View DocsDoc
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation ID
WELL05-123-42064Sater
19E-323
PDC ENERGY INC
69175
TA
9/1/2025
WATTENBERG
90750
WELD  123
NWNW 19 4N63W 6
442952
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 1643 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
Click for SpecificsFull4/23/20255/5/2025 20Down to Zero--0No Flow649653NoNoNoAnnual Test.  20 PSI blew down to 0 PSI within first few seconds of test.  No pressure or flow observed for the remainder of the test. Operator will monitor pressure and re-test according to bradenhead policy.
Click for SpecificsFull4/29/20245/6/2024 4Down to Zero--0No Flow430430NoNoNoAnnual Test.  4 PSI blew down to 0 PSI within first few seconds of test.  No pressure or flow observed for the remainder of the test. PDC will monitor pressure and re-test according to bradenhead policy.
Click for SpecificsFull4/22/20244/30/2024 0No Flow--0No Flow433433NoNoNo 
Click for SpecificsFull4/18/20234/24/2023 2Down to Zero--0Down to Zero178180NoNoneNoneAnnual Test. 2 PSI gas blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will continue to monitor monthly.
403135472Form 178/12/20228/15/2022PLUNGER LIFT111CONTINUOUS GAS0 WHISPER 249249Yes----Annual Test, 111 PSI continuous gas flow blew down to 0 PSI in 30 minutes. PDC will schedule a sampling event and submit results via form 43. PDC will continue to monitor monthly.
402834180Form 1710/5/202110/7/2021PLUNGER LIFT1DOWN TO 0 --0 NO FLOW 316316No----Abatement system follow up test, 1 PSI blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will submit sundry with bradenhead details as soon as possible. PDC will continue to monitor monthly.
Click for SpecificsFull5/8/202111/1/2021 3Down to Zero--0No Flow321321NoNoneNone 
402796178Form 1712/10/20208/30/2021PLUNGER LIFT60CONTINUOUS GAS0 NO FLOW 314314Yes----Post-production, 60 PSI gas flow blew down to 0 PSI within first 5 minutes. No pressure or flow observed for the remainder of the test. PDC will submit sundry with bradenhead details as soon as possible. PDC will schedule a sampling event and submit results via form 43.
402793046Form 1711/11/20208/26/2021CLOCK/INTERMITTER215CONTINUOUS VAPOR0 NO FLOW 277277Yes----Post-production, 215 PSI vapor flow blew down to 0 PSI within first 5 minutes. No pressure or flow observed for the remainder of the test. PDC will submit sundry with bradenhead details as soon as possible. PDC will schedule a sampling event and submit results via form 43.
Click for SpecificsLight4/24/20205/11/2020 20 --20 329329NoNoNo 
Click for SpecificsLight3/8/20198/18/2020 16 --0 360360NoNoNo