View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
404193724Form 174/25/20255/7/2025GAS LIFT54CONTINUOUS WATER AND GAS1 WHISPER 311311No----Engineering Ad Hoc test. 54 PSI gas and water blew down to 1 PSI in thirty minutes. Gas stopped after 2 minutes and water remained for entire test, ~1 gal. Operator will schedule a sampling event and submit results via form 43. Operator will continue to monitor monthly.
403846818Form 176/28/20247/8/2024PLUNGER LIFT15DOWN TO 0 WATER AND GAS0 NO FLOW 689692No----Annual test. 15 PSI water and gas flow blew down to 0 PSI in 5 minutes, ~0.25 gallons. No flow or pressure for the remainder of the test. PDC will monitor pressure and re-test according to bradenhead policy.
Click for SpecificsFull5/19/20235/29/2023 17Down to Zero--0Down to Zero798797NoNoneNoneAnnual Test. 17 PSI blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will monitor pressure and re-test according to bradenhead policy.
402940383Form 171/26/20221/28/2022FLOWING27DOWN TO 0 GAS0 NO FLOW 816817No----Retest after blowdown period and build up since 9/28/2021. Gas at open for 1 second. Dead until 3 minute mark then water for 1 minute, then dead for remainder of test. Made .25 gallon total.
402687778Form 174/16/20215/13/2021FLOWING93CONTINUOUS WATER H200 NO FLOW 456455YesNoYesTest per NTO. Water at open. Slowing to no flow at 12 minutes.
402302136Form 171/24/20202/3/2020FLOWING13WATER H20 --0 NO FLOW 458462No----Test after 5 week blowdown and 1 week buildup. water for first 5 seconds and died. Made ~ 1 pint total.
402232286Form 1711/1/201911/6/2019FLOWING105NO FLOW --0 NO FLOW 423423No----Test per NTO. Blew down to 0 almost instantly and made 1/2 quart of water. No flow throughout test.