WELL05-123-39346Kodak North FD
25-121HN
PDC ENERGY INC
69175
PR
6/1/2024
WATTENBERG
90750
WELD  123
SENW 26 6N67W 6
333035
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 1530 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
404551175Form 172/11/20262/19/2026PLUNGER LIFT37CONTINUOUS WATER AND LIQUID HYDROCARBON0 NO FLOW 342336No---- 
404384734Form 1710/2/202510/8/2025PLUNGER LIFT8DOWN TO 0 GAS0 NO FLOW 436434No----Remediation follow up test. 8 PSI blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. Operator will monitor pressure and re-test according to bradenhead policy.
404147559Form 173/19/20253/31/2025PLUNGER LIFT7DOWN TO 0 GAS0 NO FLOW 452455No----Remediation follow up test. 7 PSI blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. Operator will monitor pressure and re-test according to bradenhead policy.
Click for SpecificsFull1/21/20251/28/2025 5Down to Zero--0No Flow509506NoNoNoAnnual Test.  5 PSI blew down to 0 PSI within first few seconds of test.  No pressure or flow observed for the remainder of the test. PDC will monitor pressure and re-test according to bradenhead policy.
403718571Form 173/13/20243/13/2024PLUNGER LIFT0DOWN TO 0 GAS0 NO FLOW 618618No----Offset Well - Option 4 test. 0 PSI, slight gas at start, with no pressure or flow observed for the remainder of the 30-minute test.
Click for SpecificsFull2/13/20242/26/2024Plunger Lift11Down to Zero--0Down to Zero982982NoNoNoAnnual Test.  11 PSI blew down to 0 PSI within first few seconds of test.  No pressure or flow observed for the remainder of the test. PDC will monitor pressure and re-test according to bradenhead policy.
Click for SpecificsFull6/1/20236/12/2023 32Down to Zero--0Down to Zero670668NoNoNoAnnual Test. 32 PSI blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will monitor pressure and re-test according to bradenhead policy.
403189813Form 1710/3/202210/6/2022PLUNGER LIFT72DOWN TO 0 GAS0 NO FLOW 10321034No----Engineering Ad Hoc test. 72 PSI gas flow blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will continue to monitor monthly.
402780631Form 178/12/20218/16/2021FLOWING25CONTINUOUS GAS0 NO FLOW 951952No----Retest after build up since displacement on 3/26/2021. Gas at open for 1 minute then dead.
402618696Form 172/23/20213/4/2021FLOWING168CONTINUOUS MUD0 CONTINUOUS 544544YesNoYesTest per NTO. Non-aqueous liquid at open slowing to drips at 8 minute mark, continued for remainder of test.
402357561Form 173/25/20203/31/2020FLOWING8WHISPER --0 NO FLOW 166165No----Test after DOFP. Whisper on open, died right at the minute mark.
402283335Form 171/8/20201/13/2020SHUT-IN5DOWN TO 0 --0 NO FLOW 00No----Test prior to toe-prep/frac.