Skip to Main Content

Incident Search

 
BradenheadView Related Related View DocsDoc
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation ID
WELL05-123-39322Postle IC
11-159HC
PDC ENERGY INC
69175
PR
4/1/2025
WATTENBERG
90750
WELD  123
SWNW 11 3N68W 6
433857
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 1073 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
404247371Form 176/5/20256/19/2025GAS LIFT26CONTINUOUS WATER AND GAS1 WHISPER 582586No----Remediation follow up test. 26 PSI gas and water, blew down to 1 in thirty minutes, water continued for entire test, ~1 gal. Operator will schedule a sampling event and submit results via form 43. Operator will monitor pressure and re-test according to bradenhead policy.
403846115Form 176/28/20247/5/2024 14CONTINUOUS WATER AND GAS0 NO FLOW 568571No----Remediation follow up test. 14 PSI continuous water blew down to 0 PSI within ten minutes of test. No pressure or flow observed for the remainder of the test. PDC will monitor pressure and re-test according to bradenhead policy.
403410611Form 175/18/20235/23/2023PLUNGER LIFT51CONTINUOUS WATER AND GAS0 CONTINUOUS 535532Yes----Automation Alert Follow-Up. 51 PSI water and gas flow blew down to 0 PSI in 5 minutes. Water trickled for entire test. PDC will collect a sample and submit results via form 43. PDC will monitor pressure and re-test according to bradenhead policy.
403341038Form 173/6/20233/8/2023PLUNGER LIFT26DOWN TO 0 WATER AND GAS0 CONTINUOUS 710724Yes----Annual test. 26 PSI gas and water flow blew down to 0 PSI in 5 minutes. 1 pint fluid at open, then steady trickle for 7 minutes, and steady drip for remainder of test. PDC will schedule a sampling event and submit results via form 43. PDC will continue to monitor monthly.
403089892Form 176/24/20226/27/2022PLUNGER LIFT82DOWN TO 0 WATER H200 CONTINUOUS 600599No----Test after pressure discovery. Water on open, attempted to collect 1000mL water sample. Flow died to drip after only 250mL. Water drip for duration of test producing ~700mL total of water.
402955956Form 172/10/20222/14/2022PLUNGER LIFT11DOWN TO 0 GAS0 NO FLOW 581581No----Retest after 26 day buildup. Whisper on open for 1 second and died. No flow for remainder of test.
402763680Form 177/19/20217/29/2021FLOWING66CONTINUOUS WATER H200 CONTINUOUS 774776No----Test per NTO. Water at open. Water for entire test. Not enough for sample.
402559867Form 1712/15/202012/23/2020PLUNGER LIFT6DOWN TO 0 WATER H200 NO FLOW 10211007No----Test per 2020. Water surge on open made ~ 1/4 cup. Not enough volume for adequate sample. No flow for the remainder of the test.
Click for SpecificsLight11/1/201912/12/2019 5  0No Flow932953NoNoNoTest per NTO. BH Dead.