404247371 | Form 17 | 6/5/2025 | 6/19/2025 | GAS LIFT | 26 | CONTINUOUS | WATER AND GAS | 1 | WHISPER | 582 | 586 | No | -- | -- | Remediation follow up test. 26 PSI gas and water, blew down to 1 in thirty minutes, water continued for entire test, ~1 gal. Operator will schedule a sampling event and submit results via form 43. Operator will monitor pressure and re-test according to bradenhead policy. |
403846115 | Form 17 | 6/28/2024 | 7/5/2024 | | 14 | CONTINUOUS | WATER AND GAS | 0 | NO FLOW | 568 | 571 | No | -- | -- | Remediation follow up test. 14 PSI continuous water blew down to 0 PSI within ten minutes of test. No pressure or flow observed for the remainder of the test. PDC will monitor pressure and re-test according to bradenhead policy. |
403410611 | Form 17 | 5/18/2023 | 5/23/2023 | PLUNGER LIFT | 51 | CONTINUOUS | WATER AND GAS | 0 | CONTINUOUS | 535 | 532 | Yes | -- | -- | Automation Alert Follow-Up. 51 PSI water and gas flow blew down to 0 PSI in 5 minutes. Water trickled for entire test. PDC will collect a sample and submit results via form 43. PDC will monitor pressure and re-test according to bradenhead policy. |
403341038 | Form 17 | 3/6/2023 | 3/8/2023 | PLUNGER LIFT | 26 | DOWN TO 0 | WATER AND GAS | 0 | CONTINUOUS | 710 | 724 | Yes | -- | -- | Annual test. 26 PSI gas and water flow blew down to 0 PSI in 5 minutes. 1 pint fluid at open, then steady trickle for 7 minutes, and steady drip for remainder of test. PDC will schedule a sampling event and submit results via form 43. PDC will continue to monitor monthly. |
403089892 | Form 17 | 6/24/2022 | 6/27/2022 | PLUNGER LIFT | 82 | DOWN TO 0 | WATER H20 | 0 | CONTINUOUS | 600 | 599 | No | -- | -- | Test after pressure discovery. Water on open, attempted to collect 1000mL water sample. Flow died to drip after only 250mL. Water drip for duration of test producing ~700mL total of water. |
402955956 | Form 17 | 2/10/2022 | 2/14/2022 | PLUNGER LIFT | 11 | DOWN TO 0 | GAS | 0 | NO FLOW | 581 | 581 | No | -- | -- | Retest after 26 day buildup.
Whisper on open for 1 second and died. No flow for remainder of test. |
402763680 | Form 17 | 7/19/2021 | 7/29/2021 | FLOWING | 66 | CONTINUOUS | WATER H20 | 0 | CONTINUOUS | 774 | 776 | No | -- | -- | Test per NTO. Water at open. Water for entire test. Not enough for sample. |
402559867 | Form 17 | 12/15/2020 | 12/23/2020 | PLUNGER LIFT | 6 | DOWN TO 0 | WATER H20 | 0 | NO FLOW | 1021 | 1007 | No | -- | -- | Test per 2020. Water surge on open made ~ 1/4 cup. Not enough volume for adequate sample. No flow for the remainder of the test. |
Click for Specifics | Light | 11/1/2019 | 12/12/2019 | | 5 | | | 0 | No Flow | 932 | 953 | No | No | No | Test per NTO. BH Dead. |