WELL05-123-38965Becker Ranch
5M-323
PDC ENERGY INC
69175
SI
5/1/2025
WATTENBERG
90750
WELD  123
NWNE 5 3N64W 6
436185
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 928 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
Click for SpecificsFull4/14/20254/21/2025 4Down to Zero--0No Flow40405NoNoNoAnnual Test.  4 PSI blew down to 0 PSI within first few seconds of test.  No pressure or flow observed for the remainder of the test. Operator will monitor pressure and re-test according to bradenhead policy.
403773507Form 174/23/20244/30/2024PLUNGER LIFT4DOWN TO 0 WATER AND GAS0 NO FLOW 136139No----Annual test. 4 PSI water and gas flow blew down to 0 PSI in seconds, water continued to drip for 15 minutes. No flow or pressure for remainder of test. PDC will monitor pressure and re-test according to bradenhead policy.
403298089Form 171/20/20231/23/2023PLUNGER LIFT0NO FLOW WATER H200 NO FLOW 236241No----Abatement system follow up test, 0 PSI. 20 seconds after open water trickled for 15 seconds, then dripped for 1 minute. No pressure or flow observed for the remainder of the test. PDC will submit sundry with bradenhead details if needed as soon as possible. PDC will continue to monitor monthly.
403081305Form 176/15/20226/16/2022PLUNGER LIFT62CONTINUOUS WATER AND GAS0 CONTINUOUS 165160No----Annual Test, 62 PSI water and gas flow blew down to 0 PSI within first minute of test. No pressure observed for the remainder of the test, water was steady trickle for 15 minutes after open then steady drip last 15 minutes. PDC will schedule a sampling event and submit results via form 43 as well as a remediation plan via sundry as soon as possible. PDC will continue to monitor monthly.
Click for SpecificsFull5/26/202111/1/2021 0No Flow--0No Flow193191NoNoneNone 
Click for SpecificsLight3/2/20205/11/2020 0 --0 248248NoNoNo 
Click for SpecificsLight3/8/20198/18/2020 0 --0 227227NoNoNo