403782834 | Form 17 | 5/1/2024 | 5/7/2024 | | 6 | CONTINUOUS | WATER AND GAS | 0 | NO FLOW | 260 | 260 | Yes | -- | -- | Annual Test. 6 PSI gas and water flow blew down to 0 PSI within 15 minutes, >1 pt fluid and gas within 25 seconds to light trickle until 11 minute mark, >1 qt total fluid. PDC will continue to monitor monthly. |
403495495 | Form 17 | 8/2/2023 | 8/14/2023 | PLUNGER LIFT | 20 | CONTINUOUS | WATER AND GAS | 0 | CONTINUOUS | 272 | 272 | No | -- | -- | Abatement system follow up test. 20 PSI water and gas flow blew down to 0 PSI within first few seconds of test. Fluid trickled for entire test. PDC will submit sundry with bradenhead details as soon as possible. PDC will continue to monitor monthly. |
403298181 | Form 17 | 1/19/2023 | 1/23/2023 | SHUT-IN | 52 | DOWN TO 0 | GAS | 0 | NO FLOW | 387 | 387 | Yes | -- | -- | Automation Alert follow-up test. 52 PSI gas flow blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will schedule a sampling event and submit results via form 43. PDC will continue to monitor monthly. |
Click for Specifics | Full | 8/9/2022 | 9/6/2022 | | 43 | Down to Zero | -- | 0 | No Flow | 267 | 264 | No | None | None | Annual Test. 43 PSI blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will continue to monitor monthly. |
Click for Specifics | Full | 9/8/2021 | 11/1/2021 | | 42 | Continuous | -- | 0 | No Flow | 401 | 383 | No | None | None | |
Click for Specifics | Light | 10/10/2020 | 12/14/2020 | | 38 | | -- | 0 | | 802 | 802 | No | No | No | |
Click for Specifics | Light | 6/9/2019 | 11/27/2019 | | 0 | | | 0 | | 900 | 900 | No | No | No | |
401025884 | Form 17 | 4/11/2016 | 4/13/2016 | SHUT-IN | 7 | NO FLOW | -- | 0 | NO FLOW | 640 | 640 | No | -- | -- | Bradenhead pressure went to 0 in 2 min 38 sec. |