Click for Specifics | Full | 7/18/2024 | 7/29/2024 | | 6 | Down to Zero | -- | 0 | No Flow | 733 | 734 | No | No | No | Annual Test. 6 PSI, with no pressure or flow observed for the entire 30-minute test. PDC will monitor pressure and re-test according to bradenhead policy. |
Click for Specifics | Full | 5/4/2023 | 5/15/2023 | | 5 | Down to Zero | -- | 0 | Down to Zero | 595 | 595 | No | None | None | Annual Test. 5 PSI blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will monitor pressure and re-test according to bradenhead policy. |
403291175 | Form 17 | 1/12/2023 | 1/16/2023 | FLOWING | 237 | DOWN TO 0 | MUD | 0 | CONTINUOUS | 635 | 633 | Yes | -- | -- | Remediation Follow-Up. 237 PSI, mud on open. Produced 4 gallons and died to trickle/drip. Trickle/drip for duration of test producing 4.5 gallons of mud total. Displaced after and collected water sample. |
403051772 | Form 17 | 5/12/2022 | 5/17/2022 | FLOWING | 99 | CONTINUOUS | MUD | 0 | CONTINUOUS | 1463 | 1462 | Yes | -- | Yes | Test after DOFP. Mud on open, collected 40mL BH & Prod sample. Down to 0 PSI in 2 minutes through needle valve and died to drip. Produced about 2.5 gallons total. |
402908418 | Form 17 | 12/21/2021 | 12/23/2021 | SHUT-IN | 0 | NO FLOW | NONE | 0 | NO FLOW | 0 | 0 | No | -- | -- | Test prior to toe prep/frac. Vacuum on open |