| 403858685 | Form 17 | 7/8/2024 | 7/18/2024 | | 13 | CONTINUOUS | GAS | 0 | NO FLOW | 0 | 0 | No | -- | -- | Pre-P&A. 13 PSI gas blew down to 0 PSI in 2 minutes. No pressure or flow observed for the remainder of the test. No tubing, well was never produced. |
| 403790613 | Form 17 | 5/1/2024 | 5/15/2024 | | 0 | CONTINUOUS | GAS | 0 | NO FLOW | 0 | 0 | No | -- | -- | Delayed Completions Test. 0 PSI increased to 13 PSI gas for first 5 minutes then after 5 minutes it was a whisper and blew down to 0 PSI within fifteen minutes of test. No pressure or flow observed for the remainder of test. PDC will monitor pressure and re-test according to bradenhead policy.
|
| 403607619 | Form 17 | 11/27/2023 | 11/28/2023 | SHUT-IN | 20 | CONTINUOUS | GAS | 0 | NO FLOW | 0 | 5 | No | -- | -- | Delayed Completions Test. 20 PSI blew down to 0 PSI in 8 minutes. No pressure or flow observed for the remainder of the test. |
| 403415995 | Form 17 | 5/24/2023 | 5/30/2023 | SHUT-IN | 28 | CONTINUOUS | GAS | 0 | NO FLOW | 0 | 0 | No | -- | -- | Delayed Completions Test. 28 PSI blew down to 0 PSI in 5 minutes. No pressure or flow observed for the remainder of the test. |
| 403230987 | Form 17 | 11/15/2022 | 11/16/2022 | SHUT-IN | 30 | CONTINUOUS | GAS | 0 | NO FLOW | 0 | 0 | No | -- | -- | Delayed Completions Test. 30 PSI gas flow blew down to 0 PSI in 5 minutes. No pressure or flow observed for the remainder of the test. |
| 402723363 | Form 17 | 6/15/2021 | 6/18/2021 | SHUT-IN | 6 | DOWN TO 0 | GAS | 0 | NO FLOW | 0 | 0 | No | -- | -- | Test per NTO. Gas on open for 1 minute and 30 seconds and died. No flow for remainder of test. |
| Click for Specifics | Light | 9/4/2020 | 9/7/2020 | | 7 | | -- | 0 | No Flow | 0 | 0 | No | No | No | |
| 402223375 | Form 17 | 10/22/2019 | 10/28/2019 | SHUT-IN | 0 | NO FLOW | -- | 0 | NO FLOW | 0 | 0 | Yes | -- | -- | Test per NTO. BH dead
|