| Click for Specifics | Full | 9/4/2025 | 9/15/2025 | | 5 | Down to Zero | -- | 0 | No Flow | 0 | 0 | No | No | No | Annual Test. 5 PSI blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. Operator will monitor pressure and re-test according to bradenhead policy. |
| Click for Specifics | Full | 9/9/2024 | 9/19/2024 | | 8 | Down to Zero | -- | 0 | No Flow | 0 | 0 | No | No | No | Annual Test. 8 PSI blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will monitor pressure and re-test according to bradenhead policy. |
| Click for Specifics | Full | 10/12/2023 | 10/16/2023 | Shut In | 6 | Down to Zero | -- | 0 | No Flow | 0 | 0 | No | No | No | Annual Test. 6 PSI blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will monitor pressure and re-test according to bradenhead policy. |
| 402940292 | Form 17 | 1/18/2022 | 1/28/2022 | SHUT-IN | 4 | DOWN TO 0 | WATER H20 | 0 | NO FLOW | 9 | 10 | No | -- | -- | Test per NTO. Water drips at open. Dead by 1 minute mark. Dead for remainder of test. Made 1/2 cup total. |
| 402695498 | Form 17 | 5/17/2021 | 5/20/2021 | SHUT-IN | 7 | DOWN TO 0 | GAS | 0 | NO FLOW | 70 | 71 | No | -- | -- | Test per NTO. Whisper open, died in 2 seconds. No flow for the remainder of the test. |
| Click for Specifics | Light | 10/23/2020 | 11/9/2020 | | 5 | | -- | 0 | No Flow | 57 | 54 | No | No | No | |
| 402223435 | Form 17 | 10/23/2019 | 10/28/2019 | SHUT-IN | 17 | DOWN TO 0 | -- | 0 | NO FLOW | 162 | 162 | No | -- | -- | Test per NTO. Blew dead< 5 secs. BH dead |