| Click for Specifics | Full | 9/5/2025 | 9/15/2025 | | 16 | Continuous | -- | 0 | No Flow | 340 | 340 | No | No | No | Annual Test. 16 PSI blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. Operator will monitor pressure and re-test according to bradenhead policy. |
| Click for Specifics | Full | 9/25/2024 | 10/1/2024 | | 0 | No Flow | -- | 0 | No Flow | 900 | 900 | No | No | No | Annual Test. 0 PSI, with no pressure or flow observed for the entire 30-minute test. PDC will monitor pressure and re-test according to bradenhead policy. |
| 403520916 | Form 17 | 9/1/2023 | 9/6/2023 | PLUNGER LIFT | 16 | NO FLOW | WATER H20 | 0 | NO FLOW | 450 | 450 | No | -- | -- | Annual Test. 16 PSI gas flow blew down to 0 PSI within first few seconds of test. Intermittent water present for entire test, ~1 pint total. PDC will monitor pressure and re-test according to bradenhead policy. |
| Click for Specifics | Full | 3/29/2022 | 4/18/2022 | | 13 | Down to Zero | -- | 0 | Down to Zero | 650 | 650 | No | No | No | |
| 402898228 | Form 17 | 6/30/2021 | 12/14/2021 | PLUNGER LIFT | 10 | DOWN TO 0 | WATER H20 | 0 | NO FLOW | 700 | 700 | No | -- | -- | Engineering Ad Hoc test, 10 PSI water flow blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will continue to monitor monthly. |
| Click for Specifics | Light | 9/10/2020 | 12/3/2020 | | 0 | | -- | 0 | No Flow | 1045 | 1045 | No | No | No | |
| Click for Specifics | Light | 6/13/2019 | 11/27/2019 | | 26 | | | 0 | | 1100 | 1100 | No | No | No | |