403690590 | Form 17 | 2/14/2024 | 2/16/2024 | SHUT-IN | 23 | DOWN TO 0 | WATER H20 | 0 | NO FLOW | 380 | 380 | No | -- | -- | Pre-PA Release Bradenhead Test
WBD doc# 403656786 submitted on Form 6 doc# 403656094. Sample could not be collected due to no flow.
Insufficient liquid to sample. ~3 cups total liquid. |
Click for Specifics | Light | 4/3/2023 | 5/15/2023 | Shut-In | 26 | | -- | 0 | | 0 | 0 | No | No | No | |
Click for Specifics | Light | 2/14/2022 | 3/22/2022 | Plunger Lift | 27 | | -- | 0 | | 195 | 196 | No | No | No | Down to zero in 30 sec, surged brackish fluid next 5 min then static at 0 PSI. |
Click for Specifics | Full | 8/4/2021 | 9/6/2021 | | 30 | DOWN TO 0 | | 0 | NO FLOW | 471 | 471 | No | NO | NO | Surface casing produced gas for the first 4 minutes, when opened, then surged with dark black fluid. Unable to sample |
Click for Specifics | Full | 2/26/2020 | 3/23/2020 | | 31 | DOWN TO 0 | -- | 0 | NO FLOW | 109 | 109 | No | No | No | Surface casing blew down to 0 psi in 3:35, mostly gas with small amount of fluid. |
Click for Specifics | Light | 12/10/2019 | 12/17/2019 | | 30 | | -- | 0 | Down To Zero | 126 | 126 | No | No | No | |
401775761 | Form 17 | 7/28/2018 | 9/26/2018 | PLUNGER LIFT | 16 | WHISPER | -- | 0 | NO FLOW | 887 | 887 | No | -- | -- | |