Skip to Main Content

Incident Search

 
BradenheadView Related Related View DocsDoc
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation ID
WELL05-123-33702TANNER FEDERAL
K33-65HN
PDC ENERGY INC
69175
PR
12/8/2025
WATTENBERG
90750
WELD  123
NWSW 33 4N66W 6
423752
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 623 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
404426925Form 1711/4/202511/6/2025SHUT-IN10DOWN TO 0 WATER AND GAS0 NO FLOW 00No----Remediation follow up test. 10 PSI blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. Operator will monitor pressure and re-test according to bradenhead policy.
Click for SpecificsFull8/18/20258/25/2025 21Continuous--0No Flow518519NoNoNo Annual Test.  21 PSI blew down to 0 PSI within first few seconds of test.  No pressure or flow observed for the remainder of the test. Operator will monitor pressure and re-test according to bradenhead policy.
404218969Form 175/12/20255/27/2025SHUT-IN9CONTINUOUS GAS1 WHISPER 00No----Remediation follow up test. 9 PSI gas blew down to 1 in thirty minutes, whisper gas continued for entire test. Operator will monitor pressure and re-test according to bradenhead policy.
403898611Form 178/19/20248/22/2024 23CONTINUOUS WATER AND GAS21 CONTINUOUS 267269No----Annual test. 23 PSI water and gas flow blew down to 21 PSI in thirty minutes. Water and gas observed throughout entire test, ~5 gallons of water. PDC will schedule a sampling event and submit results via form 43. PDC will monitor pressure and re-test according to bradenhead policy.
403350856Form 173/14/20233/20/2023PLUNGER LIFT22DOWN TO 0 GAS AND LIQUID HYDROCARBON0 DOWN TO 0 272288No----Annual Test. 22 PSI water and gas flow blew down to 0 PSI within first few seconds of test. Steady stream of fluid for first 30 seconds of test, light trickle started at 2 minute mark and stopped at 26 minute mark. On and off fluid trickle for remainder of test. PDC will continue to monitor monthly.
403216074Form 1710/4/202211/2/2022PLUNGER LIFT17DOWN TO 0 WATER AND GAS0 CONTINUOUS 295286Yes----Annual Test. 17 PSI water and gas flow blew down to 0 PSI within first minute of test. Water trickled for entire test. PDC will schedule a sampling event and submit results via form 43. PDC will continue to monitor monthly.
Click for SpecificsFull9/3/202111/1/2021 22Gas--0No Flow335335NoNoneNone 
Click for SpecificsLight10/12/202012/3/2020 20 --0No Flow490490NoNoNo 
Click for SpecificsLight6/8/201911/27/2019 4  0 458458NoNoNo