View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
Click for SpecificsLight9/26/202310/9/2023SI0 --0 00NoNoNo 
403459931Form 177/5/20237/11/2023 35DOWN TO 0 GAS0 NO FLOW 00YesYes--35 PSI AT TEST START. BLEW DOWN TO 0PSI IN A ABOUT 5 SECONDS. NO FLOW FOR REMAINDER OF TEST. 0PSI AT TEST END.
403262787Form 1712/14/202212/15/2022 37NO FLOW NONE0 NO FLOW 00No----WATER SPRAYED AT START OF TEST. WATER WAS NOT CONTINUOUS. BLEWDOWN TO ZERO NO PSI NO FLOW AT END OF TEST. NOT ENOUGH WATER TO SAMPLE.
402603826Form 172/18/20212/19/2021 36CONTINUOUS GAS0 NO FLOW 867867No----GAS PRESENT AT BEGINING OF TEST. GAS WAS NOT CONTINUOUS. BLEWDOWN TO ZERO NO PSI NO FLOW AT END OF TEST. ENGINEERING REQUEST.
Click for SpecificsLight5/22/202012/16/2020PL36 --0DOWN TO 0 309327NoNoNo 
402261075Form 1712/9/201912/12/2019 34GAS --0 NO FLOW 460315No----GAS PRESENT AT BEGINING OF TEST. BLEW DOWN TO 0, NO PSI NO FLOW AT END OF TEST. ANNUAL BLOW DOWN 2019