View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
402741244Form 173/1/20217/8/2021SHUT-IN120CONTINUOUS GAS0 WHISPER 950950Yes----Pre P&A, 120 PSI continuous gas and water flow blew down to 0 PSI within thirty minutes. PDC will submit sundry with bradenhead details as soon as possible. PDC will schedule a sampling event and submit results via form 43.
402871637Form 171/21/202111/16/2021SHUT-IN110CONTINUOUS GAS AND VAPOR0 NO FLOW 980980Yes----Post-production, 110 PSI vapor and gas flow blew down to 0 PSI within 10 minutes. No pressure or flow observed for the remainder of the test. PDC will schedule a sampling event and submit results via form 43. PDC will continue to monitor monthly.
402871645Form 1712/31/202011/16/2021SHUT-IN120CONTINUOUS VAPOR2 WHISPER 10001000Yes----Post-production, 120 PSI vapor flow blew down to 2 PSI in 30 minutes. PDC will schedule a sampling event and submit results via form 43. PDC will continue to monitor monthly.
402871657Form 1711/21/202011/16/2021SHUT-IN112CONTINUOUS GAS0 NO FLOW 972972Yes----Post-production, 112 PSI gas flow blew down to 0 PSI within 10 minutes. No pressure or flow observed for the remainder of the test. PDC will schedule a sampling event and submit results via form 43. PDC will continue to monitor monthly.
402493738Form 179/16/20209/21/2020 100CONTINUOUS --0 WHISPER 968968Yes----Annual Test 100 PSI with continuous flow, blew down to 0 PSI after 30 min. PDC has collected a sample and will submit via 43 ASAP. PDC will follow up with a remediation plan via sundry.
402242368Form 1711/8/201911/18/2019PLUNGER LIFT125GAS --30 CONTINUOUS 780780Yes--YesAnnual bradenhead testing. Opened bradenhead valve, blew gas and began surging water at 5 minutes. Bradenhead will be sampled and results to be uploaded into EDD when available.