WELL05-123-30672GARCIA K
04-30D
PDC ENERGY INC
69175
PR
9/1/2025
WATTENBERG
90750
WELD  123
NENE 5 4N66W 6
326882
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 563 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
404329815Form 178/19/20258/26/2025SHUT-IN36CONTINUOUS GAS15 CONTINUOUS 00No----Annual Test. 36 PSI continuous gas blew down to 15 PSI within fifteen minutes of test. Water observed for the remainder of test. Operator will schedule a sampling event and submit results via form 43. Operator will monitor pressure and re-test according to bradenhead policy.
403763955Form 174/17/20244/22/2024SHUT-IN25WHISPER WATER AND GAS0 WHISPER 00No----Remediation follow up test. 25 PSI continuous slight water and gas flow with random surges for entire test, ~20 gallons total fluid. PDC will monitor pressure and re-test according to bradenhead policy.
403371849Form 174/10/20234/13/2023SHUT-IN35CONTINUOUS WATER AND GAS1 DOWN TO 0 800800No----Annual Test. 35 PSI blew down to 1 PSI within 30 minute test. Water was observed at start of test and than stopped. Water begin again at 11 minute mark and ended at 16 minute mark, Water started again at 10 minute mark and ended at 21 minute mark. Continuous gas was observed thru test. PDC will continue to monitor monthly.
403215310Form 1710/12/202211/1/2022SHUT-IN42CONTINUOUS WATER AND GAS15 CONTINUOUS 00No----Annual Test. 42 PSI water and gas flow blew down to 15 PSI in 30 minutes. PDC collected a gas sample 9/19/2022. PDC will continue to monitor monthly.
402779663Form 177/11/20218/13/2021SHUT-IN20WHISPER WATER AND GAS3 WHISPER 800800No----Abatement system follow up test, 20 PSI continuous gas and water flow whisper blew down to 3 PSI within thirty minutes. PDC will submit sundry with bradenhead details as soon as possible. PDC will schedule a sampling event and submit results via form 43. PDC will continue to monitor monthly.
402508959Form 1710/9/202010/12/2020 50GAS --8 GAS 720720Yes----Annual Test 50 PSI with continuous flow, blew down to 8 PSI after 30 min. PDC has collected a sample and will submit via 43 ASAP. PDC will follow up with a remediation plan via sundry.
Click for SpecificsLight6/11/201911/27/2019 0  0No Flow660660NoNoNo 
401580577Form 173/19/20183/20/2018PLUNGER LIFT43SURGE --18 SURGE 600600Yes--YesSURGED OIL FOR DURATION OF TEST. INSTANTANEOUS BUILT UP TO 18.
401525066Form 171/10/20181/24/2018PLUNGER LIFT55DOWN TO 0 --20 SURGE 600600Yes----BLEWDOWN TO ZERO SURGED OIL WHOLE TEST