| 404329815 | Form 17 | 8/19/2025 | 8/26/2025 | SHUT-IN | 36 | CONTINUOUS | GAS | 15 | CONTINUOUS | 0 | 0 | No | -- | -- | Annual Test. 36 PSI continuous gas blew down to 15 PSI within fifteen minutes of test. Water observed for the remainder of test. Operator will schedule a sampling event and submit results via form 43. Operator will monitor pressure and re-test according to bradenhead policy. |
| 403763955 | Form 17 | 4/17/2024 | 4/22/2024 | SHUT-IN | 25 | WHISPER | WATER AND GAS | 0 | WHISPER | 0 | 0 | No | -- | -- | Remediation follow up test. 25 PSI continuous slight water and gas flow with random surges for entire test, ~20 gallons total fluid. PDC will monitor pressure and re-test according to bradenhead policy. |
| 403371849 | Form 17 | 4/10/2023 | 4/13/2023 | SHUT-IN | 35 | CONTINUOUS | WATER AND GAS | 1 | DOWN TO 0 | 800 | 800 | No | -- | -- | Annual Test. 35 PSI blew down to 1 PSI within 30 minute test. Water was observed at start of test and than stopped. Water begin again at 11 minute mark and ended at 16 minute mark, Water started again at 10 minute mark and ended at 21 minute mark. Continuous gas was observed thru test. PDC will continue to monitor monthly. |
| 403215310 | Form 17 | 10/12/2022 | 11/1/2022 | SHUT-IN | 42 | CONTINUOUS | WATER AND GAS | 15 | CONTINUOUS | 0 | 0 | No | -- | -- | Annual Test. 42 PSI water and gas flow blew down to 15 PSI in 30 minutes. PDC collected a gas sample 9/19/2022. PDC will continue to monitor monthly. |
| 402779663 | Form 17 | 7/11/2021 | 8/13/2021 | SHUT-IN | 20 | WHISPER | WATER AND GAS | 3 | WHISPER | 800 | 800 | No | -- | -- | Abatement system follow up test, 20 PSI continuous gas and water flow whisper blew down to 3 PSI within thirty minutes. PDC will submit sundry with bradenhead details as soon as possible. PDC will schedule a sampling event and submit results via form 43. PDC will continue to monitor monthly. |
| 402508959 | Form 17 | 10/9/2020 | 10/12/2020 | | 50 | GAS | -- | 8 | GAS | 720 | 720 | Yes | -- | -- | Annual Test 50 PSI with continuous flow, blew down to 8 PSI after 30 min. PDC has collected a sample and will submit via 43 ASAP. PDC will follow up with a remediation plan via sundry. |
| Click for Specifics | Light | 6/11/2019 | 11/27/2019 | | 0 | | | 0 | No Flow | 660 | 660 | No | No | No | |
| 401580577 | Form 17 | 3/19/2018 | 3/20/2018 | PLUNGER LIFT | 43 | SURGE | -- | 18 | SURGE | 600 | 600 | Yes | -- | Yes | SURGED OIL FOR DURATION OF TEST. INSTANTANEOUS BUILT UP TO 18. |
| 401525066 | Form 17 | 1/10/2018 | 1/24/2018 | PLUNGER LIFT | 55 | DOWN TO 0 | -- | 20 | SURGE | 600 | 600 | Yes | -- | -- | BLEWDOWN TO ZERO SURGED OIL WHOLE TEST |