WELL05-123-28189ISHIGURO
30-31
PDC ENERGY INC
69175
SI
8/1/2025
WATTENBERG
90750
EVANS/WELD  123
NWNE 36 5N66W 6
332571
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 810 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
404309439Form 177/30/20258/7/2025SHUT-IN73DOWN TO 0 GAS0 SURGE 00No----Engineering Ad Hoc test. 73 PSI gas and water blew down to 4 PSI in thirty minutes. Gas and water observed throughout entire test. Operator will schedule a sampling event and submit results via form 43. Operator will continue to monitor monthly.
404233598Form 176/3/20256/9/2025SHUT-IN51CONTINUOUS GAS1 WHISPER 10601060No----Annual Test. 51 PSI continuous gas blew down to 1 PSI within thirty minutes of test. Gas turned to gas and liquid hydrocarbons at 7 minutes into test and continued for entire test, ~3 gals of fluid collected. Operator will schedule a sampling event and submit results via form 43. Operator will monitor pressure and re-test according to bradenhead policy.
Click for SpecificsFull1/17/20251/28/2025 25Down to Zero--0No Flow00NoNoNoAnnual Test.  25 PSI blew down to 0 PSI within first few seconds of test.  No pressure or flow observed for the remainder of the test. PDC will monitor pressure and re-test according to bradenhead policy.
404020431Form 1711/27/202412/9/2024SHUT-IN33CONTINUOUS LIQUID HYDROCARBON0 CONTINUOUS 920920No----Remediation follow up test. 33 PSI flow blew down to 0 PSI within thirty minutes, continuous liquid hydrocarbons observed throughout entire test . PDC will schedule a sampling event and submit results via form 43. PDC will monitor pressure and re-test according to bradenhead policy.
403703839Form 172/23/20242/29/2024PLUNGER LIFT25DOWN TO 0 GAS40 CONTINUOUS 570572No----Annual test. 25 PSI continuous water and gas flow increased to 40 PSI in 30 minutes, ~15 gallons fluid. PDC will schedule a sampling event and submit results via form 43. PDC will monitor pressure and re-test according to bradenhead policy.
403298142Form 171/20/20231/23/2023PLUNGER LIFT52DOWN TO 0 GAS AND LIQUID HYDROCARBON5 CONTINUOUS 698697Yes----Automation Alert follow-up test. 52 PSI gas and liquid hydrocarbon flow blew down to 0 PSI within first few seconds of test through 1/2" needle valve. At 20 minutes, gurgled and surges of same fluids. PDC will schedule a sampling event and submit results via form 43. PDC will continue to monitor monthly.
Click for SpecificsFull1/14/20222/21/2022 29Down to Zero--0No Flow656658NoNoNo 
Click for SpecificsFull5/19/202112/21/2021 29Water H2ONone3Whisper (very low flow)603606NoNoneNone 
Click for SpecificsLight11/1/202012/14/2020 0 --0 480480NoNoNo 
Click for SpecificsLight6/10/201911/27/2019 10  0No Flow626626NoNoNo 
400379997Form 171/30/20132/11/2013PLUNGER LIFT55GAS --<1 GAS 306315No----Surface casing produced no fluid during the form 17 test.
400286004Form 173/14/20125/17/2012PLUNGER LIFT66GAS --<1 WHISPER 279395No----surface casing produced no fluid