402659583 | Form 17 | 4/9/2021 | 4/15/2021 | | 115 | CONTINUOUS | GAS | 32 | CONTINUOUS | 9 | 9 | No | -- | -- | Tubing Shut in. Surface Casing produced no liquid. |
402504945 | Form 17 | 10/5/2020 | 10/7/2020 | | 127 | CONTINUOUS | -- | 1 | CONTINUOUS | 9 | 8 | No | -- | -- | Tubing Shut in. Surface Casing produced no liquid. |
402131077 | Form 17 | 7/25/2019 | 8/1/2019 | PLUNGER LIFT | 144 | GAS | -- | 4 | GAS | -- | -- | No | -- | -- | Surface casing produced no fluids. 15 minute shut in results in 93 psi. 30 minute shut in results in 4 psi. Tubing and casing shut in. |
402047292 | Form 17 | 5/6/2019 | 5/17/2019 | PLUNGER LIFT | 142 | GAS | -- | 67 | GAS | -- | -- | No | -- | -- | Surface casing produced no fluid. Well shut in for 15min ended with psi. Surface casing blown down an extra 30min ended with psi. Tubing shut in. |
401960434 | Form 17 | 2/28/2019 | 3/5/2019 | PLUNGER LIFT | 142 | GAS | -- | 66 | GAS | -- | -- | No | -- | -- | Surface casing produced no fluid. Well shut in for 15min ended with pressure. Tubing and casing shut in for horizontal offset frac. |
401604917 | Form 17 | 3/29/2018 | 4/11/2018 | | 149 | GAS | -- | 51 | GAS | 22 | 22 | Yes | Yes | -- | Surface casing produced no fluids. Blew down surface casing an extra 30 min ended with 39 PSI. Installed crystal gauge. Well and master shut in. |
401092247 | Form 17 | 8/8/2016 | 8/11/2016 | | 105 | GAS | -- | 25 | GAS | 6 | 6 | No | -- | -- | SC PRODUCED NO FLUIDS DURING TEST. BLEW DOWN SC AN EXTRA 30 MIN ENDED WITH 8 PSI. SHUT IN SC FOR 15 MIN ENDED WITH 48 PSI. WORKOVER VLAVE INSTALLED AND WELL SHUT IN |
401075420 | Form 17 | 7/8/2016 | 7/8/2016 | PLUNGER LIFT | 137 | GAS | -- | >27 | GAS | 0 | 0 | No | -- | -- | WORKOVER VALVE INSTALLED UPON ARRIVAL. SURFACE CASING PRODUCED NO FLUIDS DURING TEST. BLEW DOWN SURFACE CASING AN EXTRA 30 MIN. ENDED WITH 17 PSI. SHUT IN SURFACE CASING FOR 15 MIN. ENDED WITH 47 PSI. |
400364728 | Form 17 | 11/14/2012 | 1/4/2013 | PLUNGER LIFT | 48 | GAS | -- | <1 | GAS | 473 | 476 | No | -- | -- | Surface casing produced no fluid during the form 17 test. |