View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
403648460Form 171/8/20241/9/2024 2CONTINUOUS GAS0 NO FLOW 676676No----Tubing Shut in. Surface Casing produced no liquid.
Click for SpecificsFull7/5/20238/7/2023Plunger Lift1WhisperNone--No Flow651651NoNN Tubing Shut in. Surface Casing produced no liquid.
Click for SpecificsFull7/5/20228/9/2022Plunger Lift4ContinuousNone--No Flow718719NoNN Tubing Shut in. Surface Casing produced no liquid.
Click for SpecificsFull7/26/20218/23/2021Plunger Lift26ContinuousNone--Whisper795795NoNN Tubing Shut in. Surface Casing produced no liquid.
Click for SpecificsFull12/11/202012/21/2020Plunger Lift34Continuous----No Flow863851NoNoNo Tubing Shut in. Surface Casing produced no liquid.
402271661Form 1712/18/201912/26/2019PLUNGER LIFT13GAS --1 WHISPER 987986No----SURFACE CASING PRODUCED NO FLUIDS. TUBING SHUT IN
Click for SpecificsFull12/6/201912/20/2019 30Gas--1Gas994997NoNoNoTubing shut in. Surface casing produced no liquids.
400755071Form 1710/29/201412/18/2014PLUNGER LIFT4GAS --0 DOWN TO 0 555558No----SURFACE CASING PRODUCED NO FLUIDS DURING TEST. SHUT IN SURFACE CASING FOR 15 MINUTES ENDED WITH 0 PSI. END OF 30-DAY TEST AND AFTER 1 WEEK OF BEING SHUT IN.
400754065Form 179/23/201412/17/2014PLUNGER LIFT69GAS --1 GAS 668670No----SURFACE CASING PRODUCED NO FLUIDS DURING TEST. START OF 30-DAY TEST. LEFT SURFACE CASING OPEN TO TANK AFTER TEST.
400724222Form 179/23/201411/5/2014PLUNGER LIFT69GAS --1 GAS 668670No----SURFACE CASING PRODUCED NO FLUIDS DURING TEST. START OF 30 DAY TEST. LEFT SURFACE CASING OPEN TO TANK AFTER TEST.
400646896Form 177/17/20147/18/2014PLUNGER LIFT172GAS --1 GAS 12521253No----SURFACE CASING DID NOT PRODUCE ANY FLUID.
400499336Form 1710/7/201310/21/2013PLUNGER LIFT55GAS --10 CONTINUOUS 477490No----SURFACE CASING PRODUCED 1 GALLON OF CONDENSATE DURING TEST. BLEW DOWN SURFACE CASING FOR AN ADDITIONAL 5 HOURS. REPLUMB NOT PERFOMED DUE TO TOO MUCH PRESSURE ON SURFACE CASING.
400365051Form 1711/12/20121/4/2013PLUNGER LIFT54CONTINUOUS --29 CONTINUOUS 455459No----Surface casing produced 1 gallon of fluid during the form 17 test.