Skip to Main Content

Incident Search

 
BradenheadView Related Related View DocsDoc
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation ID
WELL05-123-26793FARMERS
2-14HZ
NOBLE ENERGY INC
100322
PA
5/12/2024
WATTENBERG
90750
WELD  123
NENE 14 3N65W 6
310680
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 868 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
403715288Form 173/9/20243/11/2024 13DOWN TO 0 VAPOR0 NO FLOW 00No----INITIAL SC PRESSURE AT 13 PSI AND BLED DOWN TO 0 IN SECONDS. NO FLUID PRESENT. PRODUCTION CSG 0 PSI
Click for SpecificsLight9/19/202310/9/2023SI0 --0 00NoNoNo 
403469633Form 177/18/20237/19/2023 13DOWN TO 0 GAS0 NO FLOW 00No----WELL TA STATUS W/ CMT & CIBP's SET. 13 psi ON SFC, DN TO ZERO IN 2 SECONDS, NO FLOW FOR REMAINDER OF THE TEST.
403385616Form 174/19/20234/26/2023 12CONTINUOUS GAS0 NO FLOW 320No----OPENED ON NEEDLE VALVE AND PRESSURE BLED DOWN TO 0 PSI IN LESS THAN ONE MINUTE NO FLUID.
403174403Form 179/21/20229/22/2022 41CONTINUOUS GAS0 NO FLOW 200200YesYes--GAS PRESENT AT BEGINING OF TEST, GAS WAS NOT CONTINUOUS. BLEW DOWN TO ZERO, NO PSI NO FLOW AT END OF TEST. GAS SAMPLE COLLECTED
403061630Form 175/24/20225/27/2022 78CONTINUOUS GAS0 NO FLOW 11201120YesYes--GAS PRESENT AT BEGINING OF TEST, GAS WAS NOT CONTINUOUS. BLEW DOWN TO ZERO, NO PSI NO FLOW AT END OF TEST. GAS SAMPLE COLLECTED. ENGINEERING REQUEST.
402760699Form 177/26/20217/27/2021 0NO FLOW NONE0 NO FLOW 991991No----NO PRESSURE ON SURFACE CASING
402586419Form 171/27/20211/29/2021 97CONTINUOUS GAS0 NO FLOW 866866YesYes--GAS PRESENT AT BEGINING OF TEST. BLEW DOWN TO ZERO, NO PSI NO FLOW AT END OF TEST. GAS SAMPLE COLLECTED.
Click for SpecificsLight5/7/202012/16/2020F15 --0DOWN TO 0 340367NoNoNo 
402327056Form 178/9/20192/28/2020 95GAS --0 NO FLOW 421431No----GAS PRESENT AT BEGINNING OF TEST. BLEW DOWN TO 0. NO PSI NO FLOW AT END OF TEST. ANNUAL BLOW DOWN 2019
400659449Form 178/5/20148/7/2014PLUNGER LIFT1WATER H20 --0 NO FLOW 381400No----Very small amount of water. Less than a quart came out during the test.
400598707Form 174/29/20144/30/2014PLUNGER LIFT540CONTINUOUS --5 CONTINUOUS 378378No----Gas sample shows bradenhead, some dilution of production gas with biogenic methane.