| 404610600 | Form 17 | 4/6/2026 | 4/10/2026 | SHUT-IN | 21 | DOWN TO 0 | GAS | 0 | NO FLOW | 500 | 500 | No | -- | -- | Pre-PA Release Bradenhead Test
|
| Click for Specifics | Light | 11/18/2025 | 11/24/2025 | | 22 | | -- | 0 | | 600 | 600 | No | No | No | |
| Click for Specifics | Light | 9/30/2024 | 10/22/2024 | | 0 | | -- | 0 | | 743 | 743 | No | No | No | |
| 403540306 | Form 17 | 9/21/2023 | 9/26/2023 | SHUT-IN | 6 | DOWN TO 0 | GAS | 0 | NO FLOW | 2 | 2 | Yes | Yes | -- | Mitigation Bradenhead Test
WBD submitted on doc# 403203081 |
| 403365580 | Form 17 | 4/4/2023 | 4/5/2023 | FLOWING | 15 | DOWN TO 0 | GAS | 0 | NO FLOW | 404 | 496 | No | -- | -- | Mitigation Bradenhead Test
WBD submitted on doc# 403203081
|
| 403203078 | Form 17 | 10/14/2022 | 10/19/2022 | SHUT-IN | 21 | DOWN TO 0 | GAS | 0 | NO FLOW | 0 | 0 | No | -- | -- | Mitigation Bradenhead Test
WBD attached |
| 403087522 | Form 17 | 6/22/2022 | 6/28/2022 | SHUT-IN | 34 | DOWN TO 0 | GAS | 0 | NO FLOW | 0 | 0 | No | -- | -- | Mitigation Bradenhead Test
WBD submitted on doc#01948512 |
| Click for Specifics | Full | 6/24/2021 | 7/12/2021 | | 109 | CONTINUOUS | -- | 0 | NO FLOW | 707 | 707 | No | YES | No | Surface casing pressure blew down to 0 psi in 5 minutes, produced only gas.
|
| 402738803 | Form 17 | 6/24/2021 | 7/6/2021 | | 109 | CONTINUOUS | GAS | 0 | NO FLOW | 707 | 707 | Yes | Yes | -- | Surface casing pressure blew down to 0 psi in 5 minutes, produced only gas. |
| Click for Specifics | Full | 12/11/2020 | 1/18/2021 | | 37 | Continuous | -- | 0 | No Flow | 0 | 0 | No | No | No | Surface casing pressure blew down to 0 psi in 15 minutes, produced only gas |
| 402555363 | Form 17 | 12/11/2020 | 12/16/2020 | | 37 | CONTINUOUS | GAS | 0 | NO FLOW | 0 | 0 | No | -- | -- | Surface casing pressure blew down to 0 psi in 15 minutes, produced only gas |
| 402450155 | Form 17 | 7/23/2020 | 7/23/2020 | SHUT-IN | 93 | SURGE | -- | 0 | NO FLOW | 0 | 0 | Yes | Yes | No | Surface casing pressure blew down to 0 psi in 6 minutes, produced gas then a dark mist. Gas sample taken. |
| 402153903 | Form 17 | 8/21/2019 | 8/23/2019 | FLOWING | 47 | GAS | -- | 0 | NO FLOW | 620 | 620 | No | -- | -- | Surface casing blew down to 0 psi in 22:30, mostly gas with a small amount of fluid. Insufficient fluid volume for sample. |
| 401694373 | Form 17 | 6/27/2018 | 7/5/2018 | SHUT-IN | 150 | DOWN TO 0 | -- | 0 | NO FLOW | 575 | 575 | No | -- | -- | Well blew down immediately. Sample was too small to measure. |
| 401272218 | Form 17 | 1/23/2015 | 5/2/2017 | FLOWING | 0 | DOWN TO 0 | -- | 0 | VAPOR | 580 | 580 | No | -- | -- | |
| 400201256 | Form 17 | 4/28/2011 | 10/11/2011 | FLOWING | 100 | DOWN TO 0 | -- | 0 | WHISPER | 700 | 700 | No | -- | -- | Slight blow after 5 minutes (too small to measure). Vented for 7 days; dead at the end of that period. |