Skip to Main Content

Incident Search

 
BradenheadView Related Related View DocsDoc
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation ID
WELL05-123-26711STEWARTS Z4
6-2 6
EXTRACTION OIL & GAS INC
10459
PA
12/8/2025
WATTENBERG
90750
WELD  123
SENW 31 5N65W 6
332851
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 1284 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
404299967Form 177/28/20257/30/2025SHUT-IN15DOWN TO 0 GAS0 NO FLOW 00No----Pre-PA Release Bradenhead Test WBD doc# 403705424 submitted on Form 6 doc# 403698381. Sample could not be collected due to insufficient flow.
403706404Form 172/28/20243/4/2024SHUT-IN2DOWN TO 0 GAS0 NO FLOW 3535No----Pre-PA Release Bradenhead Test WBD doc# 403705424 submitted on Form 6 doc# 403698381. Sample could not be collected due to no flow.
Click for SpecificsLight3/28/20234/10/2023Shut-In11 --0 00NoNoNo 
Click for SpecificsLight3/24/20224/18/2022Shut-In0 --0 00NoNoNo 
Click for SpecificsFull6/23/20217/12/2021 10DOWN TO 0 --0NO FLOW 626626NoNONOSurface casing pressure blew down to 0 psi in 30 seconds, produced only gas.
Click for SpecificsFull5/14/20206/22/2020 5DOWN TO 0  0NO FLOW 00NoNoNoSurface casing pressure blew down to 0 psi in 5 seconds, produced only gas.
402399070Form 175/14/20205/14/2020SHUT-IN5DOWN TO 0 --0 NO FLOW 00No----Surface casing pressure blew down to 0 psi in 5 seconds, produced only gas.
402154275Form 178/21/20198/23/2019FLOWING72GAS --0 NO FLOW 625625YesYes--Surface casing blew down to 0 psi in 22:45, only gas. Gas sample taken.
401694627Form 176/27/20187/5/2018SHUT-IN125DOWN TO 0 --0 NO FLOW 656656No----Well blew down immediately. Sample was too small to measure.
401273123Form 171/23/20155/2/2017FLOWING125GAS --85 GAS 500500No---- 
400201252Form 173/4/201110/11/2011FLOWING265CONTINUOUS --10 WHISPER 650650Yes----Blew down through 3/4" valve. Vented until April 18th, shut in for 7 days, and re-tested ~3-17. Fluid Sample Analysis is attached.