View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
404303282Form 177/15/20258/1/2025SHUT-IN35CONTINUOUS GAS17 CONTINUOUS 550550No----Pre-P&A. 35 PSI continuous gas and water flow blew down to 17 PSI within thirty minutes. Operator will schedule a sampling event and submit results via form 43.
404222131Form 175/14/20255/29/2025PLUNGER LIFT36CONTINUOUS GAS4 CONTINUOUS 305305No----Remediation follow up test. 36 PSI continuous gas blew down to 4 PSI within thirty minutes. Gas switched to water after 20 minutes and water continued for the remainder of test, ~4 gal. Operator will schedule a sampling event and submit results via form 43. Operator will monitor pressure and re-test according to bradenhead policy.
403905556Form 178/22/20248/29/2024SHUT-IN34CONTINUOUS WATER AND GAS0 CONTINUOUS 330330No----Annual test. 34 PSI continuous water and gas flow blew down to 0 PSI in 30 minutes, ~10 gallons total fluid. PDC will monitor pressure and re-test according to bradenhead policy.
403558209Form 1710/5/202310/12/2023PLUNGER LIFT33CONTINUOUS WATER AND GAS0 CONTINUOUS 333331No----Annual test. 33 PSI gas and fluid flow blew down to 0 PSI in 5 minutes. Strong stream of fluid continued for entire test, ~20 gallons total fluid. PDC will monitor pressure and re-test according to bradenhead policy.
403194299Form 179/26/202210/11/2022PLUNGER LIFT34CONTINUOUS WATER AND GAS2 CONTINUOUS 247259Yes----Annual Test. 34 PSI water and gas flow blew down to 2 PSI in 30 minutes through 1/2" needle valve. Water flow present the entire test. PDC will schedule a sampling event and submit results via form 43. PDC will continue to monitor monthly.
Click for SpecificsFull8/4/202112/21/2021 36Water H2ONone32Water H2O294267NoNoneNone 
Click for SpecificsLight10/8/202012/3/2020 0 --0No Flow604604NoNoNo 
Click for SpecificsLight6/6/201911/27/2019 15  0 718718NoNoNo