Skip to Main Content

Incident Search

 
BradenheadView Related Related View DocsDoc
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation ID
WELL05-123-26482SCHANK J
35-22
PDC ENERGY INC
69175
PR
9/1/2019
WATTENBERG
90750
EVANS/WELD  123
SENE 35 5N66W 6
332768
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 521 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
404487424Form 1712/16/202512/29/2025SHUT-IN30CONTINUOUS WATER H200 CONTINUOUS 430430No---- 
404450931Form 1711/7/202511/25/2025PLUNGER LIFT26CONTINUOUS WATER H204 CONTINUOUS 458342No---- 
404329783Form 178/15/20258/26/2025PLUNGER LIFT28CONTINUOUS WATER AND GAS16 CONTINUOUS 391419No----Annual Test. 29 PSI continuous water and gas blew down to 16 PSI within thirty minutes of test. Water observed for entire test, ~10 gals of fluid collected. Operator will schedule a sampling event and submit results via form 43. Operator will monitor pressure and re-test according to bradenhead policy.
404222089Form 175/14/20255/29/2025PLUNGER LIFT36CONTINUOUS GAS1 WHISPER 290300No----Remediation follow up test. 36 PSI whisper gas blew down to 1 in thirty minutes, whisper gas continued for entire test. Operator will monitor pressure and re-test according to bradenhead policy.
403905538Form 178/22/20248/29/2024SHUT-IN30CONTINUOUS WATER AND GAS0 CONTINUOUS 391391No----Annual test. 30 PSI continuous water and gas flow blew down to 0 PSI in 30 minutes. PDC will monitor pressure and re-test according to bradenhead policy.
403558205Form 1710/5/202310/12/2023PLUNGER LIFT35CONTINUOUS WATER AND GAS0 CONTINUOUS 287302Yes----Annual test. 35 PSI gas and fluid flow blew down to 0 PSI in 5 minutes. Fluid continued to trickle for entire test, ~5 gallons total fluid. PDC will monitor pressure and re-test according to bradenhead policy.
403194292Form 179/26/202210/11/2022PLUNGER LIFT35CONTINUOUS WATER AND GAS0 CONTINUOUS 282208Yes----Annual Test. 35 PSI water and gas flow blew down to 0 PSI within first minute of test through 1/2" ball valve. Water flow present the entire test. PDC will schedule a sampling event and submit results via form 43. PDC will continue to monitor monthly.
Click for SpecificsFull8/4/202112/21/2021 38Water H2ONone24Water H2O334360NoNoneNone 
Click for SpecificsLight10/8/202012/3/2020 0 --0No Flow377377NoNoNo 
Click for SpecificsLight6/6/201911/27/2019 15  0 666666NoNoNo