WELL05-123-26399WERNING
1-2B
PDC ENERGY INC
69175
SI
8/1/2022
HAMBERT
33530
EVANS/WELD  123
SENE 3 4N66W 6
332845
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 432 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
404384640Form 178/4/202510/8/2025SHUT-IN17DOWN TO 0 GAS0 NO FLOW 00No----Pre-P&A. 17 PSI blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test.
Click for SpecificsFull4/17/20254/21/2025 36Continuous--0No Flow00NoNoNoAnnual Test.  36 PSI blew down to 0 PSI within first few seconds of test.  No pressure or flow observed for the remainder of the test. Operator will monitor pressure and re-test according to bradenhead policy.
403693524Form 172/20/20242/21/2024SHUT-IN239CONTINUOUS GAS62 CONTINUOUS 14781478No----Annual test. 239 PSI continuous gas flow blew down to 62 PSI in 30 minutes. PDC will schedule a sampling event and submit results via form 43. PDC will monitor pressure and re-test according to bradenhead policy.
403452973Form 177/3/20237/5/2023SHUT-IN72CONTINUOUS WATER AND GAS0 NO FLOW 14201420Yes----Abatement system follow up test. 72 PSI water and gas flow blew down to 0 PSI within first 10 minutes of test. No pressure or flow observed for the remainder of the test. PDC will submit sundry with bradenhead details as soon as possible. PDC will continue to monitor monthly.
403361264Form 173/30/20233/30/2023SHUT-IN54CONTINUOUS GASTSTM WHISPER 13901390Yes----Abatement system follow up test. 54 PSI continuous gas flow blew down to TSTM PSI in 30 minutes. PDC will submit sundry with bradenhead details as soon as possible. PDC will continue to monitor monthly.
403303917Form 171/26/20231/27/2023SHUT-IN75CONTINUOUS GASTSTM WHISPER 13501350Yes----Annual Test. 75 PSI gas flow blew down to almost 0 PSI in 30 minutes. PDC collected a sample 8/29/2022. PDC will continue to monitor monthly.
403207085Form 1710/24/202210/25/2022SHUT-IN60CONTINUOUS GAS0 WHISPER 13501350Yes----Annual Test. 60 PSI whisper gas blew down to 0 PSI in 30 minutes. PDC collected a sample 8/29/2022. PDC will continue to monitor monthly.
402813924Form 179/13/20219/16/2021SHUT-IN15CONTINUOUS WATER AND GAS15 CONTINUOUS 11411141Yes----Annual Test, 15 PSI water and gas flow maintained pressure for the duration of the test. PDC will schedule a sampling event and submit results via form 43 as well as a remediation plan via sundry as soon as possible. PDC will continue to monitor monthly.
402720675Form 174/30/20216/16/2021SHUT-IN20CONTINUOUS WATER H2020 CONTINUOUS 993993No----Abatement system follow up test, 20 PSI continuous water flow, maintained pressure. PDC will submit sundry with bradenhead details as soon as possible. PDC will schedule a sampling event and submit results via form 43.
402777887Form 1712/20/20208/12/2021SHUT-IN60CONTINUOUS GAS0 NO FLOW 712711Yes----Abatement system follow up test, 60 PSI gas flow blew down to 0 PSI within first ten minutes of test. No pressure or flow observed for the remainder of the test. PDC will submit sundry with bradenhead details as soon as possible. PDC will continue to monitor monthly.
402440180Form 175/29/20207/9/2020 50WATER H20 --0 NO FLOW 636636Yes----Annual Test 50 PSI with continuous flow, blew down to 0 PSI after 30 min. PDC has collected a sample and will submit via 43 ASAP. PDC will follow up with a remediation plan via sundry.
Click for SpecificsLight6/7/201911/27/2019 0  0 11361136NoNoNo