| 404071341 | Form 17 | 1/16/2025 | 1/27/2025 | SHUT-IN | 0 | NO FLOW | NONE | 0 | NO FLOW | 1250 | 1250 | No | -- | -- | Pre-P&A. 0 PSI, with no flow observed for 30 minutes. |
| 403674261 | Form 17 | 1/31/2024 | 2/1/2024 | SHUT-IN | 10 | CONTINUOUS | WATER AND GAS | 0 | NO FLOW | 940 | 940 | No | -- | -- | Annual test. 10 PSI water and gas flow blew down to 0 PSI in 7 minutes. No flow or pressure for the entire test. PDC will monitor pressure and re-test according to bradenhead policy. |
| Click for Specifics | Light | 10/25/2023 | 11/13/2023 | Shut-In | 0 | | -- | 0 | | 310 | 310 | No | No | No | |
| Click for Specifics | Light | 11/16/2022 | 12/19/2022 | Shut-In | 9 | | -- | 0 | | 0 | 0 | No | No | No | |
| Click for Specifics | Light | 10/27/2021 | 11/1/2021 | Shut In | 7 | | -- | 0 | | 343 | 343 | No | No | No | |
| Click for Specifics | Light | 1/17/2020 | 2/17/2020 | | 0 | | -- | 0 | No Flow | 304 | 307 | No | No | No | |
| Click for Specifics | Light | 2/15/2019 | 12/23/2019 | | 25 | | -- | 0 | No Flow | 275 | 315 | No | No | No | |