Skip to Main Content

Incident Search

 
BradenheadView Related Related View DocsDoc
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation ID
WELL05-123-23050SEGL
4-24
PDC ENERGY INC
69175
SI
2/1/2025
WATTENBERG
90750
GREELEY/WELD  123
SENW 24 5N66W 6
336655
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 684 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
Click for SpecificsFull1/9/20261/19/2026 0No Flow--0No Flow18941894NoNoNoAnnual Test.  0 PSI, with no pressure or flow observed for the entire 30-minute test.  Operator will monitor pressure and re-test according to bradenhead policy.
Click for SpecificsFull2/5/20252/10/2025 0No Flow--0No Flow18251825NoNoNoAnnual Test.  0 PSI, with no pressure or flow observed for the entire 30-minute test.  PDC will monitor pressure and re-test according to bradenhead policy.
Click for SpecificsFull2/16/20242/26/2024Shut In0Down to Zero--0Down to Zero17001700NoNoNoAnnual Test.  0 PSI, with no pressure or flow observed for the entire 30-minute test.  PDC will monitor pressure and re-test according to bradenhead policy.
Click for SpecificsFull1/18/20231/30/2023 4Down to Zero--0No Flow852852NoNoneNoneAnnual Test. 4 PSI blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will continue to monitor monthly.
Click for SpecificsFull1/22/20222/21/2022 3Down to Zero--0No Flow176176NoNoNo 
Click for SpecificsFull6/22/202112/21/2021 2Whisper (very low flow)None1Whisper (very low flow)16001600NoNoneNone 
402614736Form 1710/13/20203/2/2021 0NO FLOW NONE0 NO FLOW 455455No----Abatement system follow up test 0 PSI no pressure or flow, PDC will monitor pressure and re-test in 6 months.
Click for SpecificsLight3/18/202012/14/2020 2 --0 200200NoNoNo 
402242658Form 1711/11/201911/18/2019PLUNGER LIFT0NO FLOW --0 CONTINUOUS 540540Yes--YesAnnual bradenhead testing. Bradenhead flowed continuous stream of fluid. Fluid sampled and results will be uploaded into EDD when available.
400353161Form 1710/15/201212/3/2012PLUNGER LIFT1GAS --0 DOWN TO 0 428442No----No fluid was produced during form 17 test.
400354521Form 1710/5/201212/5/2012PLUNGER LIFT1GAS --0 DOWN TO 0 448462No----No fluid was produced during form 17 test.
400287554Form 174/17/20125/22/2012PLUNGER LIFT1GAS --0 NO FLOW 688695No----Surface casing pressure was down to zero very quickly after opening