403357279 | Form 17 | 3/27/2023 | 3/27/2023 | | 24 | CONTINUOUS | WATER H20 | 1 | WHISPER | 620 | 620 | Yes | No | Yes | Tubing Shut in. Surface Casing produced Water. |
403175247 | Form 17 | 9/19/2022 | 9/22/2022 | | 1 | WHISPER | WATER AND GAS | 1 | WHISPER | 627 | 627 | No | -- | -- | Tubing Shut in. Surface Casing produced Water. |
Click for Specifics | Full | 12/3/2021 | 12/13/2021 | Plunger Lift | 1 | Whisper | None | -- | No Flow | 37 | 37 | No | N | N | Tubing Shut in. Surface Casing produced no liquid. |
402439400 | Form 17 | 5/27/2020 | 7/8/2020 | | 31 | CONTINUOUS | -- | 0 | NO FLOW | 691 | 692 | No | -- | -- | surface casing produced no fluids. |
Click for Specifics | Full | 12/12/2019 | 12/20/2019 | | 24 | Gas | -- | 1 | Water H2O | 703 | 700 | No | No | No | Tubing shut in. Surface casing produced water. |
400485259 | Form 17 | 8/27/2013 | 9/24/2013 | PLUNGER LIFT | 26 | WATER H20 | -- | 0 | DOWN TO 0 | 434 | 449 | No | -- | -- | SC PRODUCED <1 GALLON H20 DURING THE FORM 17 TEST. |
400286621 | Form 17 | 3/7/2012 | 5/18/2012 | PLUNGER LIFT | 23 | GAS | -- | 0 | NO FLOW | 544 | 558 | No | -- | -- | Surface casing had pressure and gas on the initial reading but dropped to 0 and stayed there for the remainder of the test. Well was equalizing. |