Skip to Main Content

Incident Search

 
BradenheadView Related Related View DocsDoc
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation ID
WELL05-123-18672WERNING
2-3
PDC ENERGY INC
69175
PA
11/17/2023
WATTENBERG
90750
EVANS/WELD  123
NWNE 3 4N66W 6
330230
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 392 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
403543025Form 179/22/20239/27/2023SHUT-IN29CONTINUOUS WATER AND GAS9 CONTINUOUS 00Yes----Pre P&A. 29 PSI water and gas flow blew down to 9 PSI in 30 minutes. Gas flow stopped after 5 minutes, water was constant strong stream for entire test, ~20 gallons. PDC will collect a sample.
403438921Form 176/14/20236/20/2023SHUT-IN30CONTINUOUS WATER AND GAS3 CONTINUOUS 10201020Yes----Pre-P&A. 30 PSI continuous gas and water flow blew down to 3 PSI within thirty minutes. PDC will schedule a sampling event and submit results via form 43.
403303927Form 171/26/20231/27/2023SHUT-IN52CONTINUOUS WATER AND GAS30 CONTINUOUS 00Yes----Annual Test. 52 PSI gas and water blew down to 30 PSI in 30 minutes. Water present for entire test at solid stream, 15 gallons of water over test. PDC will schedule a sampling event and submit results via form 43. PDC will continue to monitor monthly.
403206952Form 1710/24/202210/25/2022SHUT-IN30CONTINUOUS WATER AND GAS5 CONTINUOUS 00No----Abatement system follow up test. 30 PSI continuous gas and water flow blew down to 5 PSI within thirty minutes. PDC will submit sundry with bradenhead details as soon as possible. PDC collected a water and gas sample 3/16/2022 . PDC will continue to monitor monthly.
403036986Form 174/12/20225/3/2022SHUT-IN34CONTINUOUS WATER AND GAS26 CONTINUOUS 948948Yes----Annual Test, 34 PSI slight water and gas blew down to 26 PSI in 30 minutes with continuous water flow for the duration of the test. PDC will schedule a sampling event and submit results via form 43 as well as a remediation plan via sundry as soon as possible. PDC will continue to monitor monthly.
Click for SpecificsFull7/30/202112/21/2021 38Water H2ONone35Water H2O892892NoNoneNone 
Click for SpecificsLight10/2/202012/3/2020 35 --0No Flow265265NoNoNo 
Click for SpecificsLight6/7/201911/27/2019 35  0 825825NoNoNo