| 402750861 | Form 17 | 7/15/2021 | 7/19/2021 | | 34 | DOWN TO 0 | NONE | 0 | NO FLOW | 200 | 200 | Yes | Yes | -- | 30 MIN BH TEST 200/200/34, BLED SURFACE DOWN TO 0 PSI. THERE WAS NO CHANGE IN THE TBG & CSG PSI DURING THE TEST AND NO FLUID OR VENTING FROM THE SURFACE CSG.
|
| Click for Specifics | LIGHT | 4/6/2021 | 5/11/2021 | SI | 25 | | -- | 0 | DOWN TO 0 | 609 | 609 | No | No | No | |
| 402375222 | Form 17 | 4/17/2020 | 4/20/2020 | | 22 | GAS | -- | 0 | NO FLOW | 360 | 296 | No | -- | -- | GAS PRESENT AT START OF TEST. GAS WAS NOT CONTINUOUS. BLEW DOWN TO ZERO. NO FLOW AT END OF TEST. CLOSE OUT FORM 4. |
| 402039244 | Form 17 | 5/3/2019 | 5/10/2019 | PLUNGER LIFT | 25 | GAS | -- | 0 | NO FLOW | 531 | 531 | Yes | -- | Yes | GAS PRESENT AT START OF TEST THEN BLEWDOWN. SPRAYED WATER AT 5 MIN. MARK FOR 4 MIN. BLEW DOWN TO 0, NO PSI NO FLOW AT END OF TEST. WATER SAMPLE COLLECTED.
ANNUAL BLOW DOWN 2019 |