Skip to Main Content

Incident Search

 
BradenheadView Related Related View DocsDoc
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation ID
WELL05-123-16547MCCLELLAN
33-20
PDC ENERGY INC
69175
PA
10/21/2025
WATTENBERG
90750
WELD  123
NWSE 20 4N66W 6
328874
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 326 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
404380441Form 179/17/202510/6/2025SHUT-IN0NO FLOW NONE0 NO FLOW 00No----Remediation follow up test. 0 PSI, no pressure or flow observed for entire of the test. Operator will monitor pressure and re-test according to bradenhead policy.
404222463Form 175/15/20255/29/2025SHUT-IN0NO FLOW NONE0 NO FLOW 00No----Remediation follow up test. 0 PSI, no pressure or flow observed. Operator will monitor pressure and re-test according to bradenhead policy.
404450310Form 172/14/202511/25/2025SHUT-IN26CONTINUOUS WATER H200 CONTINUOUS 11001100No----Previously submitted on 2/24/2025, DOC#: 404104055 but regulatory requested withdraw due to typo on test date so we could re-submit w/correct test date on this DOC. Pre-P&A. 26 PSI continuous water flow blew down to 1 PSI within thirty minutes. Operator will schedule a sampling event and submit results via form 43.
Click for SpecificsLight1/23/20252/3/2025 5 --0 11501140NoNoNo 
403669295Form 171/26/20241/29/2024SHUT-IN23CONTINUOUS WATER AND GAS0 CONTINUOUS 960960No----Annual test. 23 PSI gas and steady stream of water flow on open. Fluid continued to trickle until 12 minute mark, then dripped for remainder of test, ~11 gallons total fluid. PDC will schedule a sampling event and submit results via form 43. PDC will monitor pressure and re-test according to bradenhead policy.
403301162Form 171/16/20231/25/2023SHUT-IN23DOWN TO 0 WATER AND GAS0 CONTINUOUS 940940No----Annual Test. 23 PSI gas and water blew down to 0 PSI within first minute of test. 1/2 gallon fluid at open, then steady stream for 7 minutes, then steady trickle for 2 minute, then steady drip for remainder of test. PDC will continue to monitor monthly.
Click for SpecificsFull4/22/20225/9/2022 0Down to Zero--0Down to Zero900900NoNoNo 
Click for SpecificsFull9/11/202111/1/2021 20Water H2O--0No Flow870870NoNoneNone 
Click for SpecificsLight11/21/202012/3/2020 0 --0No Flow450450NoNoNo 
Click for SpecificsLight6/11/201911/27/2019 10  0 400400NoNoNo 
400436255Form 175/28/20136/19/2013PLUNGER LIFT24WATER H20 --10 WATER H20 334336No----Surface casing produced 5 gallons of H2O during test.
400286342Form 173/13/20125/18/2012PLUNGER LIFT24CONTINUOUS --<1 WHISPER 341348No----Surface casing produced 10 gallons of condensate