| 404381092 | Form 17 | 9/26/2025 | 10/6/2025 | SHUT-IN | 14 | DOWN TO 0 | WATER H20 | 0 | WHISPER | 900 | 900 | No | -- | -- | Pre-P&A. 14 PSI whisper water blew down to 0 PSI within first few seconds of test. Trickle water observed for entire test, not enough to sample. |
| Click for Specifics | Light | 1/30/2025 | 2/3/2025 | | 0 | | -- | 0 | | 0 | 0 | No | No | No | |
| 403728858 | Form 17 | 3/22/2024 | 3/22/2024 | SHUT-IN | 3 | WHISPER | WATER AND GAS | 0 | WHISPER | 0 | 0 | No | -- | -- | Annual test. 3 PSI water and gas flow blew down to 0 PSI in one minute, whisper gas for entire test. PDC will monitor pressure and re-test according to bradenhead policy. |
| 403284581 | Form 17 | 1/9/2023 | 1/10/2023 | SHUT-IN | 9 | CONTINUOUS | WATER AND GAS | 0 | CONTINUOUS | 800 | 800 | Yes | -- | -- | Annual Test. 9 PSI gas and slight water blew down to 0 PSI within first minute of test. Steady fluid trickle until 7 minute mark and then on and off dripping for remainder of test. PDC will schedule a sampling event and submit results via form 43. PDC will continue to monitor monthly. |
| Click for Specifics | Full | 4/12/2022 | 5/9/2022 | | 0 | No Flow | -- | 0 | No Flow | 0 | 0 | No | No | No | |
| Click for Specifics | Full | 8/4/2021 | 11/1/2021 | | 10 | Down to Zero | -- | 0 | No Flow | 0 | 0 | No | None | None | |
| Click for Specifics | Light | 10/17/2020 | 12/3/2020 | | 10 | | -- | 0 | No Flow | 201 | 201 | No | No | No | |
| Click for Specifics | Light | 6/11/2019 | 11/27/2019 | | 0 | | | 0 | No Flow | 280 | 280 | No | No | No | |