| 402087071 | Form 17 | 4/19/2019 | 6/25/2019 | PLUNGER LIFT | 50 | GAS | -- | 12 | WHISPER | 530 | 530 | Yes | -- | -- | Annual Test 50 PSI whisper blew down to 12 PSI after 30 min. PDC has collected a sample and will submit via 43 ASAP. PDC will follow up with a remediation plan via sundry. |