| 404109120 | Form 17 | 1/7/2025 | 2/27/2025 | SHUT-IN | 40 | CONTINUOUS | WATER AND GAS | 0 | CONTINUOUS | 840 | 0 | No | -- | -- | Pre-P&A. 40 PSI water and gas blew down to 0 PSI within thirty minutes of test. Continuous gas observed throughout entire test. |
| Click for Specifics | Full | 8/26/2024 | 9/4/2024 | | 40 | Continuous | -- | 0 | Down to Zero | 827 | 827 | No | No | No | Annual Test. 40 PSI blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will monitor pressure and re-test according to bradenhead policy. |
| 403553567 | Form 17 | 10/5/2023 | 10/9/2023 | SHUT-IN | 39 | DOWN TO 0 | GAS | 5 | CONTINUOUS | 0 | 0 | Yes | -- | -- | Annual test. 39 PSI gas flow blew down to 0 PSI in seconds. At 10 minute mark steady stream of fluid started and lasted for remainder of test, ~15 gallons total. Instantaneous Bradenhead pressure at end of test was 5 PSI. PDC will monitor pressure and re-test according to bradenhead policy. |
| 403215340 | Form 17 | 10/28/2022 | 11/1/2022 | SHUT-IN | 36 | DOWN TO 0 | WATER AND GAS | 2 | CONTINUOUS | 745 | 745 | Yes | -- | -- | Annual Test. 36 PSI water and gas flow blew down to 2 PSI in 30 minutes PDC will schedule a sampling event and submit results via form 43 as well as a remediation plan via sundry as soon as possible. PDC will continue to monitor monthly. |
| Click for Specifics | Full | 4/9/2021 | 12/21/2021 | | 30 | Continuous | None | 5 | Continuous | 650 | 650 | No | None | None | |
| Click for Specifics | Light | 10/2/2020 | 12/14/2020 | | 1 | | -- | 0 | | 498 | 498 | No | No | No | |
| Click for Specifics | Light | 6/6/2019 | 11/27/2019 | | 15 | | | 0 | | 551 | 551 | No | No | No | |
| 400477016 | Form 17 | 7/26/2013 | 9/5/2013 | PLUNGER LIFT | 37 | WATER H20 | -- | 10 | WATER H20 | 378 | 343 | No | -- | -- | SURFACE CASING PRODUCED 150 GALLONS DURING A 3 HOUR PERIOD WAITING FOR WELL TO DIE. AFTER WELL DIED, PERFORM REPLUMB. |
| 400491252 | Form 17 | 3/4/2013 | 10/7/2013 | PLUNGER LIFT | 27 | WATER H20 | -- | 0 | DOWN TO 0 | 340 | 348 | No | -- | -- | SURFACE CASING PRODUCED <1 GALLON OF H20 DURING THE FORM 17 TEST. |