Skip to Main Content

Incident Search

 
BradenheadView Related Related View DocsDoc
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation ID
WELL05-123-13289PEPPLER
3-36
PDC ENERGY INC
69175
PA
2/4/2025
WATTENBERG
90750
EVANS/WELD  123
SWNW 36 5N66W 6
323623
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 516 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
404109120Form 171/7/20252/27/2025SHUT-IN40CONTINUOUS WATER AND GAS0 CONTINUOUS 8400No----Pre-P&A. 40 PSI water and gas blew down to 0 PSI within thirty minutes of test. Continuous gas observed throughout entire test.
Click for SpecificsFull8/26/20249/4/2024 40Continuous--0Down to Zero827827NoNoNoAnnual Test.  40 PSI blew down to 0 PSI within first few seconds of test.  No pressure or flow observed for the remainder of the test. PDC will monitor pressure and re-test according to bradenhead policy.
403553567Form 1710/5/202310/9/2023SHUT-IN39DOWN TO 0 GAS5 CONTINUOUS 00Yes----Annual test. 39 PSI gas flow blew down to 0 PSI in seconds. At 10 minute mark steady stream of fluid started and lasted for remainder of test, ~15 gallons total. Instantaneous Bradenhead pressure at end of test was 5 PSI. PDC will monitor pressure and re-test according to bradenhead policy.
403215340Form 1710/28/202211/1/2022SHUT-IN36DOWN TO 0 WATER AND GAS2 CONTINUOUS 745745Yes----Annual Test. 36 PSI water and gas flow blew down to 2 PSI in 30 minutes PDC will schedule a sampling event and submit results via form 43 as well as a remediation plan via sundry as soon as possible. PDC will continue to monitor monthly.
Click for SpecificsFull4/9/202112/21/2021 30ContinuousNone5Continuous650650NoNoneNone 
Click for SpecificsLight10/2/202012/14/2020 1 --0 498498NoNoNo 
Click for SpecificsLight6/6/201911/27/2019 15  0 551551NoNoNo 
400477016Form 177/26/20139/5/2013PLUNGER LIFT37WATER H20 --10 WATER H20 378343No----SURFACE CASING PRODUCED 150 GALLONS DURING A 3 HOUR PERIOD WAITING FOR WELL TO DIE. AFTER WELL DIED, PERFORM REPLUMB.
400491252Form 173/4/201310/7/2013PLUNGER LIFT27WATER H20 --0 DOWN TO 0 340348No----SURFACE CASING PRODUCED <1 GALLON OF H20 DURING THE FORM 17 TEST.