| Click for Specifics | Light | 1/25/2023 | 2/13/2023 | Plunger Lift | 2 | | -- | 0 | | 222 | 222 | No | No | No | |
| 403326187 | Form 17 | 1/25/2023 | 2/22/2023 | PLUNGER LIFT | 2 | DOWN TO 0 | GAS | 0 | NO FLOW | 222 | 222 | No | -- | -- | Pre-PA Release Bradenhead Test
WBD doc# 403315344 submitted on Form 6 doc# 403315303
|
| Click for Specifics | Light | 1/24/2022 | 2/21/2022 | Flowing | 0 | | -- | 0 | | 80 | 98 | No | No | No | |
| 402571254 | Form 17 | 1/7/2021 | 1/14/2021 | FLOWING | 0 | NO FLOW | NONE | 0 | NO FLOW | 117 | 94 | No | -- | -- | Case 1/3. 0 psig. initial surface casing pressure. No samples taken. |
| 402448477 | Form 17 | 7/16/2020 | 7/22/2020 | FLOWING | 3 | DOWN TO 0 | -- | 0 | NO FLOW | 156 | 147 | No | -- | -- | Annual. Case 1/3. 3 psig BHP. Down to 0 w/in 5 minutes. |
| Click for Specifics | Full | 1/14/2019 | 12/24/2019 | | 0 | No Flow | -- | 0 | No Flow | 94 | 100 | No | No | No | Short surface casing. Below bradenhead threshold. No mitigation or Form 4 required. |
| 400864825 | Form 17 | 7/2/2015 | 7/8/2015 | | 0 | WHISPER | -- | 0 | NO FLOW | 103 | 103 | No | -- | -- | VERIFIED PRESSURE AT 0 PSI
WHISPER THEN NO FLOW
|