| 404238549 | Form 17 | 6/12/2025 | 6/12/2025 | PLUNGER LIFT | 2 | DOWN TO 0 | -- | 0 | NO FLOW | 84 | 85 | No | -- | -- | |
| 403825166 | Form 17 | 6/13/2024 | 6/14/2024 | FLOWING | 4 | DOWN TO 0 | -- | 0 | NO FLOW | 82 | -- | No | -- | -- | |
| 403441460 | Form 17 | 6/21/2023 | 6/21/2023 | PLUNGER LIFT | 4 | DOWN TO 0 | -- | 0 | NO FLOW | 102 | -- | No | -- | -- | BH blew down in 3 sec thru 2" valve. |
| 403052292 | Form 17 | 5/17/2022 | 5/17/2022 | PLUNGER LIFT | 18 | DOWN TO 0 | -- | 0 | NO FLOW | 79 | -- | No | -- | -- | |
| 402714285 | Form 17 | 6/9/2021 | 6/10/2021 | FLOWING | 12 | DOWN TO 0 | -- | 0 | | 98 | -- | No | -- | -- | BH blew down in 6 sec thru 2" valve. |
| 402170223 | Form 17 | 6/12/2019 | 9/9/2019 | FLOWING | 9 | DOWN TO 0 | -- | 0 | NO FLOW | 88 | 100 | No | -- | -- | BH blew down instantaniously and remained at NF for the remainder of the test. |
| 400867070 | Form 17 | 7/7/2015 | 7/13/2015 | PUMPING | 36 | DOWN TO 0 | -- | 0 | NO FLOW | 88 | 89 | No | -- | -- | |
| 400663572 | Form 17 | 8/6/2014 | 8/13/2014 | PUMPING | 36 | DOWN TO 0 | -- | 0 | NO FLOW | 86 | 86 | No | -- | -- | |
| 400441386 | Form 17 | 6/25/2013 | 7/1/2013 | PUMPING | 0 | NO FLOW | -- | 0 | NO FLOW | 101 | 101 | No | -- | -- | |
| 2515158 | Form 17 | 7/8/2012 | 7/8/2012 | PUMPING | 0 | DOWN TO 0 | -- | 0 | DOWN TO 0 | 102 | 102 | No | -- | -- | |