WELL05-045-21712WPX Energy
GM 341-12
TEP ROCKY MOUNTAIN LLC
96850
PR
3/15/2013
GRAND VALLEY
31290
GARFIELD  045
SESE 1 7S96W 6
324080
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 1132 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
404296050Form 177/28/20257/28/2025PLUNGER LIFT108CONTINUOUS WATER AND GAS0 NO FLOW 153151No----This Form 17 is being submitted to satisfy a COA attached to Doc# 404080081. The test was performed through a 1/2" valve and the well cycled during the test.
404184667Form 174/29/20254/30/2025PLUNGER LIFT199CONTINUOUS GAS0 NO FLOW 158163No----This is an annual bradenhead test that was performed after a seven-day shut-in period. The bradenhead is connected to the sales line with an approved pressure management plan. The test was performed through a 1/2 inch valve. Well cycled during test.
404030355Form 1712/16/202412/16/2024PLUNGER LIFT329CONTINUOUS GAS0 WHISPER 128126No----TEP has initiated a diagnostic evaluation of the well due to the bradenhead threshold pressure exceedance. The bradenhead test was performed through a 1/2" valve.
Click for SpecificsFull1/23/20242/5/2024Plunger Lift299N/A--0No Flow132130NoNoNo1/2" Blowdown
Click for SpecificsFull2/10/20233/15/2023Plunger Lift235N/A--0No Flow138139NoNoNo1/2 valve
Click for SpecificsFull10/19/202211/8/2022Plunger Lift166N/A--0No Flow134139NoNoNo 
Click for SpecificsFull5/13/20216/7/2021Plunger Lift199N/A--0No Flow138143NoNoNo 
Click for SpecificsLight10/1/20156/2/2020 --  130 ----NoNoNo