Skip to Main Content

Incident Search

 
BradenheadView Related Related View DocsDoc
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation ID
WELL05-045-19731ExxonMobil
GM 523-27
TEP ROCKY MOUNTAIN LLC
96850
PR
8/31/2011
GRAND VALLEY
31290
GARFIELD  045
SESW 27 6S96W 6
335397
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 727 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
404534982Form 171/29/20262/5/2026PLUNGER LIFT158CONTINUOUS GAS0 NO FLOW 128131No----This is an annual bradenhead test that was performed after a seven-day shut-in period. The well has an approved pressure management plan. The test was performed through a 1/2 inch valve.
404125658Form 173/11/20253/13/2025PLUNGER LIFT163CONTINUOUS GAS0 WHISPER 136141No----This is an annual bradenhead test that was performed after a seven-day shut-in period. The bradenhead is connected to the flow line with an approved pressure management plan. The test was performed through a 1/2 inch valve.
403698663Form 172/23/20242/26/2024PLUNGER LIFT102CONTINUOUS GAS0 NO FLOW 150150No----This is an annual bradenhead test using the ECMC approved pilot testing procedure for 2024 which does not involve a seven-day shut-in of the connected bradenhead prior to performing the test. The bradenhead is connected to the flowline with an approved pressure management plan. The test was performed through a 1/2" valve.
403404183Form 175/16/20235/16/2023PLUNGER LIFT167CONTINUOUS GAS0 NO FLOW 142147No----This is an annual bradenhead test that was performed after a seven-day shut-in period. The bradenhead is connected to the flowline with an approved pressure management plan. The test was performed through a 1/2" valve.
403254890Form 1712/8/202212/8/2022PLUNGER LIFT220CONTINUOUS GAS0 NO FLOW 160160No----Performed through a 1/2" valve.
Click for SpecificsFull4/25/20225/16/2022Plunger Lift170N/A--0No Flow162161NoNoNo1/2” blow down
Click for SpecificsFull10/6/202110/25/2021Plunger Lift108N/A--0No Flow155155NoNoNo 
402552151Form 1712/14/202012/15/2020SHUT-IN210DOWN TO 0 NONE0 DOWN TO 0 148146No---- 
Click for SpecificsLight10/1/20156/2/2020 --  200 ----NoNoNo