| 404214357 | Form 17 | 5/19/2025 | 5/22/2025 | CLOCK/INTERMITTER | 158 | CONTINUOUS | GAS | 0 | NO FLOW | 90 | 92 | No | -- | -- | This is an annual bradenhead test that was performed on day six of the seven-day shut-in period due to the bradenhead exceeding the threshold pressure. The bradenhead is connected to the flow line with an approved pressure management plan. The test was performed through a 2 inch valve. |
| 403804840 | Form 17 | 5/28/2024 | 5/28/2024 | CLOCK/INTERMITTER | 164 | CONTINUOUS | GAS | 0 | WHISPER | 125 | 126 | No | -- | -- | This is an annual bradenhead test that was performed on Day Six of the seven-day shut-in period due to the bradenhead exceeding the threshold pressure. The bradenhead is connected to the flow line with an approved pressure management plan. The test was performed through a 2 inch valve. |
| Click for Specifics | Full | 6/21/2023 | 7/17/2023 | Clock/Intermitter | 60 | N/A | -- | 60 | N/A | 123 | 62 | No | No | No | tied in to sales |
| Click for Specifics | Full | 3/14/2022 | 4/18/2022 | Clock/Intermitter | 68 | N/A | -- | 68 | N/A | 146 | 136 | No | No | No | tied into tubing |
| Click for Specifics | Full | 6/30/2021 | 7/12/2021 | Shut-In | 107 | N/A | -- | 0 | Down to Zero | 219 | 225 | No | No | No | Tied into flow line. |
| 402317736 | Form 17 | 2/19/2020 | 2/20/2020 | SHUT-IN | 152 | GAS | -- | 0 | DOWN TO 0 | 598 | 217 | No | -- | -- | |
| Click for Specifics | Light | 6/19/2019 | 6/2/2020 | | 44 | | | 0 | | -- | -- | No | No | No | |
| Click for Specifics | Light | 5/9/2017 | 6/2/2020 | | 46 | | | 0 | | -- | -- | No | No | No | |
| Click for Specifics | Light | 6/15/2016 | 6/2/2020 | | 45 | | | 0 | | -- | -- | No | No | No | |
| 2221315 | Form 17 | 1/12/2011 | 1/20/2011 | FLOWING | 157 | DOWN TO 0 | -- | 0 | NO FLOW | 0 | 0 | Yes | Yes | No | TUBING AND PRODUCTION CASING PRESSURES NOT REPORTED BY THE OPERATOR FOR THIS TEST. ACTUAL PRESSURES UNKNOWN, BUT ZERO WAS ENTERED FOR THE PRODUCTION CASING PRESSURE TO PROCESS THIS FORM AND AVOID FORM 17 VALIDATION ERRORS. OPERATOR COMMENTS: BRADENHEAD SHUT-IN PRESSURE AFTER 48 HOURS BUILT TO 150 PSI. PER BLM INSTRUCTION, THE BRADENHEAD WAS OPENED AT THIS POINT AND THEN SHUT BACK IN ON 1/10/2011. ON THE MORNING OF 1/12/2011, THE BRADENHEAD PRESSURE WAS 157 PSI. THE VALVE WAS THEN FULLY OPENED TO BLOW DOWN THE PRESSURE. THE GAS VENTED FOR APPROXIMATELY 1 MINUTE AND 39 SECONDS BEFORE REACHING 0 PSI. AT THE END OF THE BRADENHEAD TEST, THE BRADENHEAD VALVE WAS LEFT OPEN TO VENT. |
| Click for Specifics | Light | 10/14/2010 | 6/2/2020 | | -- | | | 0 | | -- | -- | No | No | No | |
| Click for Specifics | Light | 10/2/2010 | 6/2/2020 | | -- | | | -- | | -- | -- | No | No | No | |