| 404512689 | Form 17 | 1/20/2026 | 1/20/2026 | PLUNGER LIFT | 232 | CONTINUOUS | GAS | 0 | NO FLOW | 129 | 131 | No | -- | -- | This is an annual bradenhead test that was performed on day one of the seven-day shut-in period. The bradenhead is connected to the flow line with an approved pressure management plan. The test was performed through a 2 inch valve. Intermediate test was performed through a 1/2 inch valve. |
| 404110860 | Form 17 | 2/26/2025 | 2/28/2025 | PLUNGER LIFT | 112 | CONTINUOUS | GAS | 0 | WHISPER | 1929 | 1933 | No | -- | -- | This test is part of a 60-day diagnostic period that TEP initiated. Bradenhead was tested through a 2" valve and intermediate was tested through a 1/2" valve. |
| 404087753 | Form 17 | 2/6/2025 | 2/10/2025 | PLUNGER LIFT | -- | | NONE | 0 | | -- | -- | No | -- | -- | TEP has initiated an diagnostic evaluation due to the bradenhead threshold pressure exceedance. The test was
performed through a 2" valve. Intermediate test was cancelled due to safety concerns of a hole in intermediate casing that will be diagnosed during the 60 day period.
All intermediate pressures were filled in as "0" with "No Flow" and "No Fluid" in order to submit the test. |
| 404060852 | Form 17 | 1/15/2025 | 1/16/2025 | PLUNGER LIFT | 159 | CONTINUOUS | GAS | 0 | WHISPER | 225 | 211 | No | -- | -- | This is an annual bradenhead test that was performed on day two of the seven-day shut-in period due to the bradenhead exceeding the threshold pressure. The bradenhead is connected to the flow line with an approved pressure management plan. The bradenhead test was performed through a 2 inch valve and intermediate is plumbed with 1/2 inch blowdown. Well cycled during test. |
| 403848749 | Form 17 | 7/9/2024 | 7/9/2024 | CLOCK/INTERMITTER | 160 | CONTINUOUS | GAS | 0 | WHISPER | 115 | 112 | No | -- | -- | This is an annual bradenhead test that was performed on Day One of the seven-day shut-in period due to the bradenhead exceeding the threshold pressure. The bradenhead is connected to the flow line with an approved pressure management plan. The test was performed through a 2 inch valve and intermediate is plumbed with 1/2" blowdown. |
| Click for Specifics | Full | 7/14/2023 | 8/14/2023 | Flowing | 91 | N/A | -- | 88 | N/A | 501 | 514 | No | No | No | Tied In BH INT 1/2 Blowdown |
| Click for Specifics | Full | 2/10/2022 | 3/7/2022 | Clock/Intermitter | 128 | N/A | -- | 129 | N/A | 123 | 120 | No | No | No | tied into tubing |
| Click for Specifics | Full | 8/26/2021 | 9/6/2021 | Plunger Lift | 135 | N/A | -- | 135 | No Flow | 130 | 130 | No | No | No | Tied into sales |
| 402501268 | Form 17 | 9/24/2020 | 10/1/2020 | FLOWING | 330 | GAS | -- | 80 | GAS | 102 | 102 | No | -- | -- | Bradenhead starting psi was 330 blown down thru a 1/2 needle valve. |
| 402198418 | Form 17 | 9/30/2019 | 10/3/2019 | FLOWING | 403 | GAS | -- | 1 | GAS | 1307 | 1322 | No | -- | -- | Bradenhead initial pressure started at 403 blew down thru a ½ inch needle valve to 1 psi. |
| 401806603 | Form 17 | 10/12/2018 | 10/23/2018 | CLOCK/INTERMITTER | 380 | CONTINUOUS | -- | 0 | DOWN TO 0 | 1145 | 1163 | No | -- | -- | Bradenhead psi at start was 3880, blew down bradenhead thru 1/2 inch needle valve at end of test bradenhead psi was at 0. |
| 401420766 | Form 17 | 9/21/2017 | 10/5/2017 | FLOWING | 180 | GAS | -- | 180 | GAS | 337 | 338 | No | -- | -- | Bled down braidenhead for 30 min through 1/2 inch needle valve, final psi was 80. |
| Click for Specifics | Light | 9/20/2017 | 6/2/2020 | | 180 | | Gas | 80 | | -- | -- | No | No | No | |
| 401138077 | Form 17 | 10/21/2016 | 10/27/2016 | CLOCK/INTERMITTER | 220 | GAS | -- | 0 | WHISPER | 525 | 334 | No | -- | -- | blew down through 2" line it took 23 min to go to 0 psi
|
| Click for Specifics | Light | 10/11/2016 | 6/2/2020 | | 210 | | | 0 | | -- | -- | No | No | No | |
| Click for Specifics | Light | 10/1/2015 | 6/2/2020 | | 70 | | | 0 | | -- | -- | No | No | No | |
| Click for Specifics | Light | 12/24/2014 | 6/2/2020 | | 70 | | | 0 | | -- | -- | No | No | No | Took less than 2 min. to blow down to 0 psi - Blew down thru 2" line |
| Click for Specifics | Light | 1/14/2012 | 6/2/2020 | | 33 | | | 0 | | -- | -- | No | No | No | |
| Click for Specifics | Light | 1/22/2011 | 6/2/2020 | | 120 | | Mud | 0 | | -- | -- | Yes | No | Yes | |