WELL05-045-07035DOE
RM-2-8
TEP ROCKY MOUNTAIN LLC
96850
PR
12/1/2010
RULISON
75400
GARFIELD  045
NESE 8 6S94W 6
335743
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 794 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
404503396Form 171/5/20261/13/2026FLOWING236CONTINUOUS GAS0 WHISPER 122119No----This is an annual bradenhead test that was performed on day three of the seven-day shut-in period. The bradenhead is connected to the flow line with an approved pressure management plan. The test was performed through a 1/2 inch valve. Well manual open flowing during test.
404194375Form 175/7/20255/7/2025PLUNGER LIFT220CONTINUOUS GAS0 WHISPER 118115No----This is an annual bradenhead test that was performed on day one of the seven-day shut-in period due to the bradenhead exceeding the threshold pressure. The bradenhead is connected to the flow line with an approved pressure management plan. The test was performed through a 1/2 inch valve.
403706640Form 173/1/20243/4/2024CLOCK/INTERMITTER136CONTINUOUS GAS0 WHISPER 144144No----This is an annual bradenhead test using the ECMC approved pilot testing procedure for 2024 which does not involve a seven-day shut-in of the connected bradenhead prior to performing the test. The bradenhead is connected to the sales separator with an approved pressure management plan. The test was performed through a 1/2" valve.
403306778Form 171/27/20231/31/2023PLUNGER LIFT248CONTINUOUS GAS1 CONTINUOUS 158159No----This is an annual bradenhead test that was performed on day three of the seven-day shut-in period due to the bradenhead exceeding the threshold pressure. The bradenhead is connected to the sales line with an approved pressure management plan. The test was performed through a 1/2" valve.
Click for SpecificsFull3/25/20224/18/2022Flowing142N/A--134N/A199199NoNoNoTied in
Click for SpecificsFull7/6/20218/9/2021Flowing276N/A--2Continuous438440NoNoNo 
402739525Form 177/6/20217/7/2021PLUNGER LIFT276CONTINUOUS GAS2 CONTINUOUS 438440No---- 
Click for SpecificsLight10/1/20156/2/2020 --  260 ----NoNoNo