WELL05-045-06410FRIPORT
14-22
TEP ROCKY MOUNTAIN LLC
96850
PR
11/21/1982
MAMM CREEK
52500
GARFIELD  045
SESW 22 6S92W 6
322506
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 998 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
404545662Form 172/4/20262/13/2026CLOCK/INTERMITTER88CONTINUOUS GAS0 NO FLOW 3335No----This is an annual bradenhead test that was performed after a seven-day shut-in period. This well has an approved pressure management plan. The test was performed through a 2 inch valve. Intermediate test performed through 1/2" valve.
404175749Form 174/23/20254/23/2025CLOCK/INTERMITTER103CONTINUOUS GAS0 WHISPER 3638No----This is an annual bradenhead test that was performed after a seven-day shut-in period. The bradenhead is connected to the flow line with an approved pressure management plan. The bradenhead test was performed through a 2 inch valve. Intermediate test was performed through a 1/2 inch valve.
403872382Form 177/29/20247/31/2024CLOCK/INTERMITTER132CONTINUOUS GAS0 WHISPER 4738No----This is an annual bradenhead test that was performed after a seven-day shut-in period. The bradenhead is connected to the flow line with an approved pressure management plan. The test was performed through a 2 inch valve. Intermediate test was performed through a 1/2 inch valve.
403495073Form 178/11/20238/14/2023CLOCK/INTERMITTER428CONTINUOUS GAS2 CONTINUOUS 4343No----TEP staff identified this well as a three string well and that the previous operator had inadvertently connected the intermediate casing to the flowline instead of the bradenhead. Staff excavated around the wellhead and located the buried bradenhead valve. The bradenhead was tested through a 2" valve and the intermediate casing was tested through a 1/2" valve.
Click for SpecificsFull2/22/20223/7/2022Plunger Lift51N/A--51N/A251257NoNoNotied in
Click for SpecificsFull6/29/20217/12/2021Shut-In73N/A--73N/A265265NoNoNobradenhead is tied into tubing and selling.
402413698Form 176/3/20206/4/2020PLUNGER LIFT158GAS --0 VAPOR 218227No----Bradenhead left open and added to flow test list per Craig Burger.
Click for SpecificsLight6/19/20196/2/2020 2  0 ----NoNoNo 
Click for SpecificsLight6/13/20176/2/2020 0  0 ----NoNoNo 
Click for SpecificsLight6/22/20166/2/2020 5  0 ----NoNoNo