Skip to Main Content

Incident Search

 
BradenheadView Related Related View DocsDoc
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation ID
WELL05-045-06231CLOUGH
20
TEP ROCKY MOUNTAIN LLC
96850
PA
11/21/2023
RULISON
75400
GARFIELD  045
SWSW 15 6S94W 6
335068
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 712 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
403557244Form 1710/11/202310/11/2023PLUNGER LIFT2DOWN TO 0 GAS0 NO FLOW 163164No----This Form 17 is being submitted to satisfy the bradenhead testing COA that was attached to the approved Form 6-NOI (Doc# 403500790). An intermediate casing test was not performed due to the previously reported production casing leak (Doc# 403455357) and safety concerns with performing an intermediate casing test. The bradenhead was not sampled, as the surface casing pressure was 2 psi and below the greater than 25 psi sampling requirement noted in the COA. The test was performed through a 1/2" valve.
403412933Form 175/24/20235/25/2023SHUT-IN2CONTINUOUS GAS0 NO FLOW 166167No----This is an annual test. Both the surface and intermediate casing tests were performed through a 1/2" valve.
Click for SpecificsFull4/8/20225/16/2022Plunger Lift8N/A--0No Flow167167NoNoNo1/2” blowdown
Click for SpecificsFull5/26/20216/7/2021Plunger Lift47N/A--0No Flow184185NoNoNo 
Click for SpecificsLight10/1/20156/2/2020 --  0 ----NoNoNo