WELL05-043-06221Pathfinder
2
AUSCO PETROLEUM INC
10412
SI
12/1/2025
FLORENCE-CANON CITY
24600
FREMONT  043
NWNW 12 20S70W 6
429093
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 1225 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
404361866Form 179/9/20259/20/2025PUMPING16CONTINUOUS VAPOR0 NO FLOW 8080No----Note: This Form 17, Doc #404361866 for Pathfinder #2 was intended to be filled out 9/19/25 for a test run on 9/09/25. Its filing was to follow a Form 17 for the Amerigo Vespucci #1 which was attempted on 9/19/25. However, a glitch occurred and the form could not be corrected until the evening of 9/20/25. This notation is also included in the comments section of Doc #404361722 (a circulating blue icon would not complete its cycle and not allow any data to be entered, saved or submitted. IT help at ECMC was not available). Numerous attempts were made to complete Form 17 for both wells, with no success. Therefore, this Form 17 is one day past the 10-day, after test, reporting period.
403925211Form 179/9/20249/17/2024PUMPING14WHISPER VAPOR0 NO FLOW 399399No----Bradenhead conducted on 9/09/24.
403641035Form 177/20/20231/5/2024SHUT-IN29CONTINUOUS VAPOR0 NO FLOW 426426No----AusCo Petroleum produced the Pathfinder #2 well and converted casinghead gas to electricity via generators at the Bitcoin site on this lease thru January 2023. The well was shut in for modifications for new generators and Bitcoin expansion at time of bradenhead testing. Evaluations continue and plans to restart the Bitcoin operation are underway.
403222082Form 1711/4/202211/12/2022PUMPING32CONTINUOUS GAS AND VAPOR0 NO FLOW 298298No----Operator conducted a bradenhead test on the subject well while well was pumping and supplying oil & gas via a 2" line to an indirect fired 3-phase separator. Both casing and tubing flowing pressures were reading 298 psi via a common flowline to separator. Operator will be conducting an MIT within a few weeks, requiring the downhole equipment be pulled to run isolation tools to conduct the MIT and then rerun tubing, pump, and rods. Another bradenhead test will be conducted prior to returning the well to production.
403308076Form 174/13/20221/31/2023SHUT-IN52CONTINUOUS VAPOR38 CONTINUOUS 426--No----