WELL05-014-20749Livingston
S19-25-11C
EXTRACTION OIL & GAS INC
10459
PR
8/1/2023
WATTENBERG
90750
BROOMFIELD/BROOMFIELD  014
NWSE 7 1S68W 6
455317
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 1596 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
403772647Form 174/25/20244/30/2024FLOWING63SURGE WATER H200 SURGE 541541No----Mitigation Bradenhead Test WBD submitted on doc# 402386651.
403573711Form 1710/23/202310/27/2023FLOWING29DOWN TO 0 GAS0 NO FLOW 693691No----Mitigation Bradenhead Test WBD submitted on doc#402386651
403396065Form 175/5/20235/8/2023FLOWING114DOWN TO 0 WATER H200 NO FLOW 833833YesYes--Mitigation Bradenhead Test WBD submitted on doc# 402386651
403061030Form 175/19/20225/26/2022FLOWING91DOWN TO 0 WATER H200 NO FLOW 990989No----Mitigation Bradenhead Test WBD submitted on doc#402386651 Water. Down to 0 in 5 seconds.
402895384Form 1711/24/202112/10/2021 183DOWN TO 0 WATER H200 NO FLOW 13091309YesNoYesForm 17 submitted to update doc # 402880541 which mistakenly reported no samples. A liquid sample was collected on 11/24/2021.
Click for SpecificsFull4/28/20215/31/2021 120DOWN TO 0  0NO FLOW 16481648NoYESNo Surface casing pressure blew down to 0 psi in 30 seconds, produced gas and surged oil
402699881Form 174/28/20215/25/2021 120DOWN TO 0 GAS AND LIQUID HYDROCARBON0 NO FLOW 16481648YesYes--Surface casing pressure blew down to 0 psi in 30 seconds, produced gas and surged oil
402390803Form 175/4/20205/5/2020FLOWING12DOWN TO 0 --0 NO FLOW 23352334No----Surface casing pressure blew down to 0 psi in 10 seconds, produced only gas.
Click for SpecificsLight11/21/201912/12/2019 0  0No Flow00NoNoNoSurface casing opened to a vacuum, no outward flow.
402400868Form 1711/21/20195/18/2020FLOWING0NO FLOW --0 NO FLOW 00No----Test was previously bulk uploaded, resubmitting for eForm record of test. No pressures or flows on surface casing. Blew down in under 30 seconds.