Skip to Main Content

Incident Search

 
BradenheadView Related Related View DocsDoc
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation ID
WELL05-005-07167STATE OF CO
5-24XXHZ
RENEGADE OIL & GAS COMPANY LLC
74165
SI
4/1/2023
DJ HORIZONTAL NIOBRARA
16950
ARAPAHOE  005
NENE 24 5S65W 6
423626
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 2407 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
404309971Form 177/31/20258/7/2025SHUT-IN3DOWN TO 0 GAS AND VAPOR0 NO FLOW 250250No----Annual 2025 bradenhead pressure test as required by ECMC rule.
404037786Form 1712/16/202412/21/2024SHUT-IN0NO FLOW NONE0 NO FLOW 506506No----Annual 2024 bradenhead pressure test as required by ECMC rule.
403593049Form 1711/12/202311/13/2023SHUT-IN2DOWN TO 0 NONE0 NO FLOW 245245No----Annual 2023 bradenhead pressure test as required by ECMC rule.
403235089Form 1711/20/202211/20/2022PUMPING3DOWN TO 0 GAS AND VAPOR0 NO FLOW 1616No---- Annual 2022 bradenhead pressure test as required by COGCC rule.
402902912Form 1712/16/202112/17/2021PUMPING8DOWN TO 0 GAS0 NO FLOW 2121No----2021 annual bradenhead test as required per COGCC wellbore integrity rules.
402556699Form 1711/12/202012/18/2020PUMPING1DOWN TO 0 GAS0 NO FLOW 3232No----Confirmation bradenhead test for State of Colorado 5-24HZ that no significant bradenhead pressure has redeveloped since the blowdown of the pressure found 12/30/2019. Several tests since 12/30/2019 have also found only minimal pressure on the bradenhead.
402487934Form 179/11/20209/14/2020SHUT-IN2DOWN TO 0 --0 NO FLOW 5050No----2020 bradenhead test performed on the State of CO 5-24XXHZ as required per adoption of COGCC rule to test all wells located in Arapahoe County.
402356152Form 173/27/20203/30/2020SHUT-IN2DOWN TO 0 --0 NO FLOW 4343No----When the initial annual bradenhead test was performed on 12/30/2019 at the State of Colorado #5-24 HZ a bradenhead pressure of 56 psi was found exceeding the COGCC guidance of 50 psi. Pressure was bled off and only a whisper was present after 10 minutes. The bradenhead pressure was checked again 24 hours after the first test on 12/31/2019 and only 1 psi was present. The 1 psi blew down and no flow was noted. An additional followup bradenhead test performed on 1/23/2020 found less than 1 psi and blew down instantly. This submittal is for an additional followup test performed on 3/26/2020. Less than 2 psi was found on the bradenhead and blew down instantly. Surface casing setting depth of the State of Colorado #5-24 HZ is 2370 feet and covers all fresh water aquifers. Bradenhead pressure of the State of Colorado #5-24 HZ will be continued to be monitored per COGCC guidelines. This test closes any additional action required as a result of the initial anomaly found on 12/30/2019.
402296347Form 171/23/20201/28/2020SHUT-IN1DOWN TO 0 --0 NO FLOW 7474No----When the initial annual bradenhead test was performed on 12/30/2019 at the State of Colorado #5-24 HZ a bradenhead pressure of 56 psi was found exceeding the COGCC guidance of 50 psi. Pressure was bled off and only a whisper was present after 10 minutes. The bradenhead pressure was checked again 24 hours after the first test and only 1 psi was present. The 1 psi blew down rapidly and no flow was noted. This submittal is for a followup bradenhead test performed on 1/23/2020. The bradenhead pressure had only rebuilt to less than 1 psi in 24 days and blew down instantly. Surface casing setting depth of the State of Colorado #5-24HZ is 2370 feet and covers all fresh water aquifers. Bradenhead pressure of the State of Colorado #5-24HZ will be monitored monthly for COGCC guidance compliance
402274794Form 1712/30/20191/2/2020PUMPING56GAS --0 WHISPER 7373No----Initial bradenhead test performed on the State of Colorado #5-24 HZ as required per adoption of COGCC new rule to test all wells located in Arapahoe County. Well had 56# on the bradenhead at the beginning of the test. The pressure blew down relatively quickly indicating a high fluid level. Only a very very faint blow remanded after 30 minutes. The bradenhead was checked again 24 hours after the test and found approximately 1# rebuilt back on the bradenhead which blew down rapidly. The pressure will be checked again in a couple of weeks to access whether a more significant problem exists. A gas sample will be taken if pressure is elevated.