WELL05-001-10371Baseline LE
06-149HN
PDC ENERGY INC
69175
PR
8/4/2020
WATTENBERG
90750
ADAMS  001
NWNE 2 1S67W 6
460375
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 1789 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
Click for SpecificsFull11/12/202511/17/2025 1Continuous--0No Flow488490NoNoNo Annual Test.  1 PSI blew down to 0 PSI within first few seconds of test.  No pressure or flow observed for the remainder of the test. Operator will monitor pressure and re-test according to bradenhead policy.
Click for SpecificsFull10/16/202410/22/2024 0No Flow--0No Flow581581NoNoNoAnnual Test.  0 PSI, with no pressure or flow observed for the entire 30-minute test.  PDC will monitor pressure and re-test according to bradenhead policy.
Click for SpecificsFull11/6/202311/22/2023Plunger Lift2Down to Zero--0Down to Zero558557NoNoNoAnnual Test. 2 PSI blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will monitor pressure and re-test according to bradenhead policy.
Click for SpecificsFull11/30/202212/12/2022 0Down to Zero--0Down to Zero572570NoNoNo 
Click for SpecificsLight9/1/20219/6/2021Plunger Lift0 --0 451449NoNoNoTest per NTO. BH dead.
402470997Form 178/18/20208/19/2020FLOWING0NO FLOW --0 NO FLOW 22No----Test after DOFP. BH dead.
402374129Form 174/9/20204/17/2020SHUT-IN0NO FLOW --0 NO FLOW 00No----Test prior to toe prep/frac. Vacuum on open.