403756580 | Form 17 | 4/12/2024 | 4/16/2024 | PLUNGER LIFT | 36 | DOWN TO 0 | WATER AND GAS | 0 | CONTINUOUS | 381 | 380 | No | -- | -- | Annual test. 36 PSI water and gas flow blew down to 0 PSI in seconds, water continued to trickle for entire test, ~1.25 gallons. PDC will monitor pressure and re-test according to bradenhead policy. |
403313055 | Form 17 | 2/1/2023 | 2/6/2023 | PLUNGER LIFT | 59 | DOWN TO 0 | WATER H20 | 0 | CONTINUOUS | 391 | 390 | No | -- | -- | Abatement system follow up test. 59 PSI water on open, collected 1000mL sample. Produced ~ 1 gallon and died to trickle.
Intermittent trickle for duration of test, produced ~1.5 gallons total. PDC will submit sundry with bradenhead details as soon as possible. PDC will continue to monitor monthly. |
403177507 | Form 17 | 9/23/2022 | 9/26/2022 | PLUNGER LIFT | 72 | CONTINUOUS | GAS | 0 | NO FLOW | 307 | 307 | Yes | -- | -- | High Pressure Confirmation test, 72 PSI blew down to 0 PSI within 5 minutes through 1/2" needle valve with no flow or pressure for the remainder of the test. PDC will schedule a sampling event and submit results via form 43. PDC will continue to monitor monthly. |
403032438 | Form 17 | 4/26/2022 | 4/29/2022 | FLOWING | 55 | DOWN TO 0 | GAS | 0 | NO FLOW | 314 | 314 | Yes | -- | Yes | Retest, build up since 4/8/2022.
Gas on open for 10 seconds then died. No flow for remainder of test.
Pulled water sample from displacement tool. |
402795906 | Form 17 | 8/26/2021 | 8/30/2021 | FLOWING | 61 | DOWN TO 0 | GAS | 0 | NO FLOW | 397 | 396 | No | -- | -- | Retest after displacement and 12 day buildup. Gas for 40 seconds at open then dead for remainder of test. |
402298945 | Form 17 | 1/21/2020 | 1/30/2020 | FLOWING | 99 | WATER H20 | -- | 0 | WATER H20 | 969 | 969 | No | -- | -- | Test after 5 week blowdown and 1 week buildup. Blew down in ~ 1 minute to trickle and down to intermittent drip at 15 minute mark. Made ~ 3.5 gallons total during test.
Water sample was collected during 2019 NTO test and phase has not changed since then. No sample was collected. |
402137648 | Form 17 | 8/5/2019 | 8/8/2019 | FLOWING | 98 | WATER H20 | -- | 0 | WATER H20 | 2147 | 2148 | Yes | -- | Yes | Test After DOFP. Blow down to 50 psi and made water. BH PSI after 1980 ml sample was 38 PSI. Blew down to trickle. Made 2.5 gals total. |
401992675 | Form 17 | 3/29/2019 | 4/2/2019 | SHUT-IN | 0 | NO FLOW | -- | 0 | NO FLOW | 0 | 0 | No | -- | -- | Test prior to toe prep/frac. |