Skip to Main Content

Incident Search

 
BradenheadView Related Related View DocsDoc
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation ID
WELL05-001-10255Schaefer LD
13-032HN
PDC ENERGY INC
69175
PR
4/27/2019
WATTENBERG
90750
ADAMS  001
SWSE 24 1S67W 6
440718
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 1788 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
Click for SpecificsFull11/10/202511/17/2025 0No Flow--0No Flow329324NoNoNoAnnual Test.  0 PSI, with no pressure or flow observed for the entire 30-minute test.  Operator will monitor pressure and re-test according to bradenhead policy.
Click for SpecificsFull4/15/20244/16/2024 0Down to Zero--0Down to Zero338331NoNoNoAnnual Test.  0 PSI, with no pressure or flow observed for the entire 30-minute test.  PDC will monitor pressure and re-test according to bradenhead policy.
Click for SpecificsFull4/14/20234/24/2023 0Down to Zero--0Down to Zero270274NoNoneNoneAnnual Test. 0 PSI, with no pressure or flow observed for the entire 30-minute test. PDC will continue to monitor monthly.
Click for SpecificsFull10/11/202211/8/2022Plunger Lift4Down to Zero--0Down to Zero257258NoNoneNone 
402839904Form 179/30/202110/13/2021FLOWING0NO FLOW NONE0 NO FLOW 333331No----Retest after displacement and build up since 5/21/2021. Dead at open.
402611097Form 172/17/20212/25/2021FLOWING66DOWN TO 0 GAS0 CONTINUOUS 311310YesYesNoTest per NTO. Sampled gas then 2 seconds of gas at open then dead until 3 minute mark when water trickle started. Didnt make enough water for sample.
402388374Form 175/1/20205/4/2020FLOWING5GAS --0 NO FLOW 606607No----Test after displacment and 40 day build up. Gas for 14 seconds then dead.
402306686Form 171/28/20202/7/2020FLOWING18WHISPER --0 NO FLOW 11191111No----Test after 5 week blowdown and 12 day buildup. Whisper of gas at open and dead in 3 seconds.
402192200Form 179/28/20199/28/2019FLOWING130WATER H20 --0 WATER H20 12331233Yes--YesTest after discovery. BH had water on open. Collected 1980 ml water sample, BH pressure after collection was 8 PSI. Drip of water for duration of test. Made ~ 2500 ml total during test.
402084389Form 176/14/20196/21/2019SHUT-IN10NO FLOW --0 NO FLOW 13691375No----Test after DOFP. Bled down to 0 in 10 seconds.
401967703Form 173/7/20193/11/2019SHUT-IN0NO FLOW --0 NO FLOW 00No----Test prior to toe prep/frac.