| Click for Specifics | Full | 11/10/2025 | 11/17/2025 | | 0 | No Flow | -- | 0 | No Flow | 329 | 324 | No | No | No | Annual Test. 0 PSI, with no pressure or flow observed for the entire 30-minute test. Operator will monitor pressure and re-test according to bradenhead policy. |
| Click for Specifics | Full | 4/15/2024 | 4/16/2024 | | 0 | Down to Zero | -- | 0 | Down to Zero | 338 | 331 | No | No | No | Annual Test. 0 PSI, with no pressure or flow observed for the entire 30-minute test. PDC will monitor pressure and re-test according to bradenhead policy. |
| Click for Specifics | Full | 4/14/2023 | 4/24/2023 | | 0 | Down to Zero | -- | 0 | Down to Zero | 270 | 274 | No | None | None | Annual Test. 0 PSI, with no pressure or flow observed for the entire 30-minute test. PDC will continue to monitor monthly. |
| Click for Specifics | Full | 10/11/2022 | 11/8/2022 | Plunger Lift | 4 | Down to Zero | -- | 0 | Down to Zero | 257 | 258 | No | None | None | |
| 402839904 | Form 17 | 9/30/2021 | 10/13/2021 | FLOWING | 0 | NO FLOW | NONE | 0 | NO FLOW | 333 | 331 | No | -- | -- | Retest after displacement and build up since 5/21/2021. Dead at open. |
| 402611097 | Form 17 | 2/17/2021 | 2/25/2021 | FLOWING | 66 | DOWN TO 0 | GAS | 0 | CONTINUOUS | 311 | 310 | Yes | Yes | No | Test per NTO. Sampled gas then 2 seconds of gas at open then dead until 3 minute mark when water trickle started. Didnt make enough water for sample. |
| 402388374 | Form 17 | 5/1/2020 | 5/4/2020 | FLOWING | 5 | GAS | -- | 0 | NO FLOW | 606 | 607 | No | -- | -- | Test after displacment and 40 day build up. Gas for 14 seconds then dead. |
| 402306686 | Form 17 | 1/28/2020 | 2/7/2020 | FLOWING | 18 | WHISPER | -- | 0 | NO FLOW | 1119 | 1111 | No | -- | -- | Test after 5 week blowdown and 12 day buildup. Whisper of gas at open and dead in 3 seconds. |
| 402192200 | Form 17 | 9/28/2019 | 9/28/2019 | FLOWING | 130 | WATER H20 | -- | 0 | WATER H20 | 1233 | 1233 | Yes | -- | Yes | Test after discovery. BH had water on open. Collected 1980 ml water sample, BH pressure after collection was 8 PSI. Drip of water for duration of test. Made ~ 2500 ml total during test. |
| 402084389 | Form 17 | 6/14/2019 | 6/21/2019 | SHUT-IN | 10 | NO FLOW | -- | 0 | NO FLOW | 1369 | 1375 | No | -- | -- | Test after DOFP. Bled down to 0 in 10 seconds. |
| 401967703 | Form 17 | 3/7/2019 | 3/11/2019 | SHUT-IN | 0 | NO FLOW | -- | 0 | NO FLOW | 0 | 0 | No | -- | -- | Test prior to toe prep/frac. |